EUVIMEDEUVIMED entdecken
Open Access

Prospective Comparison of T1-SPACE and MPRAGE for the Identification of Intrinsic T1 Hyperintensity in Patients with Intracranial Melanoma Metastases

Arian Lasocki iD, Stephen L Stuckey iD, Lauren Caspersz, Jing Xie iD, Grant A McArthur iD

American Journal of Neuroradiology · 2023

DOI: 10.3174/ajnr.a7975 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Neuroradiology, 2023. Verfasst von Arian Lasocki und 4 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Cancer Imaging (A.L., S.L.S., L.C.), Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia arian.lasocki@petermac.org. Hauptthemen laut MEDLINE: Melanoma, Brain Neoplasms, Neoplasms, Second Primary. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Peter MacCallum Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND PURPOSE: Volumetric TSE (3D-TSE) techniques are increasingly replacing volumetric magnetization-prepared gradient recalled-echo (3D-GRE) sequences due to improved metastasis detection. In addition to providing a baseline for assessing postcontrast enhancement, precontrast T1WI also identifies intrinsic T1 hyperintensity, for example, reflecting melanin or blood products. The ability of precontrast 3D-TSE to demonstrate intrinsic T1 hyperintensity is not clear from the literature; thus, this study compares precontrast 3D-TSE and 3D-GRE sequences for identifying intrinsic T1 hyperintensity in patients with metastatic melanoma. MATERIALS AND METHODS: Patients with metastatic melanoma and previously reported intrinsic T1 hyperintensity were identified. MRIs were performed at 3T including both 3D-GRE (MPRAGE) and 3D-TSE T1 sampling perfection with application-optimized contrasts by using different flip angle evolution (T1-SPACE) sequences precontrast. Axial 1-mm slices of both T1WI sequences were independently reviewed by 2 neuroradiologists, comparing the conspicuity of each lesion between the 2 sequences according to a 5-point scale and assessing whether the intrinsic T1 hyperintensity was attributable to melanin, blood products, or both. RESULTS: Twenty examinations were performed, with a total of 214 lesions demonstrating intrinsic T1 hyperintensity. Both readers found that intrinsic T1 hyperintensity was less conspicuous with T1-SPACE compared with MPRAGE for most lesions assessed (81.8%, averaged across both readers), including for lesions with intrinsic T1 hyperintensity attributable to melanin and blood products. Intrinsic T1 hyperintensity was rarely more conspicuous on T1-SPACE (1.4%). CONCLUSIONS: Precontrast intrinsic T1 hyperintensity is more conspicuous with MPRAGE than T1-SPACE. In patients with metastatic melanoma, 3D-GRE should be preferred as the precontrast T1WI sequence when both 3D-TSE and 3D-GRE are performed postcontrast and when not administering IV contrast.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MelanomaBrain NeoplasmsNeoplasms, Second PrimaryHumansMelaninsMagnetic Resonance Imaging

Substanzen

Melanins

Autor:innen und Institutionen

  • From the Department of Cancer Imaging (A.L., S.L.S., L.C.), Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia arian.lasocki@petermac.org.
  • Sir Peter MacCallum Department of Oncology (A.L., S.L.S., G.A.M.), The University of Melbourne, Parkville, Victoria, Australia.
  • Department of Radiology (A.L.), The University of Melbourne, Parkville, Victoria, Australia.
  • From the Department of Cancer Imaging (A.L., S.L.S., L.C.), Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.
  • School of Clinical Sciences at Monash Health (S.L.S.), Monash University, Clayton, Victoria, Australia.
  • Department of Medical Imaging and Radiation Sciences (S.L.S.), Monash University, Clayton, Victoria, Australia.

ORCID-Profile: Arian Lasocki, Stephen L Stuckey, Jing Xie, Grant A McArthur

Förderung

  • Peter MacCallum Foundation

Zitieren

APA

Lasocki, A., Stuckey, S. L., Caspersz, L., Xie, J., & McArthur, G. A. (2023). Prospective Comparison of T1-SPACE and MPRAGE for the Identification of Intrinsic T1 Hyperintensity in Patients with Intracranial Melanoma Metastases. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a7975

Vancouver

Lasocki A, Stuckey SL, Caspersz L, Xie J, McArthur GA. Prospective Comparison of T1-SPACE and MPRAGE for the Identification of Intrinsic T1 Hyperintensity in Patients with Intracranial Melanoma Metastases. American Journal of Neuroradiology. 2023. doi:10.3174/ajnr.a7975

BibTeX
@article{Lasocki2023,
  author = {Lasocki, Arian and Stuckey, Stephen L and Caspersz, Lauren and Xie, Jing and McArthur, Grant A},
  title = {Prospective Comparison of T1-SPACE and MPRAGE for the Identification of Intrinsic T1 Hyperintensity in Patients with Intracranial Melanoma Metastases},
  journal = {American Journal of Neuroradiology},
  year = {2023},
  doi = {10.3174/ajnr.a7975}
}
Kostenlos starten →