EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A Transitional Study for Clinical Implementation of Deep Learning-Accelerated Brain MRI: DWI, FLAIR, and SWI in a Healthy Cohort

Hee Sang Oh, Yo Han Jung, Bio Joo, Mina Park, Sang Hyun Suh, Kwon-Duk Seo, Kyung-Yul Lee, Sung Jun Ahn

Journal of Neurosonology and Neuroimaging · 30.06.2026 · 18 (1) · 16-25

DOI: 10.31728/jnn.2026.00179 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neurosonology and Neuroimaging, erschienen am 30.06.2026. Verfasst von Hee Sang Oh und 7 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Korea Health Industry Development Institute, Ministry of Health and Welfare, Ministry of Trade, Industry and Energy.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Deep learning-based reconstruction techniques have enabled the substantial acceleration of magnetic resonance imaging (MRI) acquisitions. However, before clinical implementation, their effects on the image quality and structural fidelity across commonly used brain MRI sequences must be systematically evaluated under controlled conditions. This study prospectively evaluated the image quality and technical feasibility of an Accel-DLR-based MRI protocol compared to a conventional protocol in healthy volunteers.

Methods

This prospective, single-center study enrolled 17 healthy adults (20–60 years) between May and October 2025. All participants underwent both conventional and Accel-DLR brain MRI using a 3T scanner, including diffusion-weighted imaging (DWI), susceptibility-weighted imaging (SWI), and fluid-attenuated inversion recovery (FLAIR). Qualitative image quality (overall quality, structural delineation, and artifacts) was assessed by radiologists, and the signal-to-noise ratios (SNR) were quantitatively compared.

Results

Accel-DLR reduced total acquisition time by 51.2% (447.6 s vs. 218.4 s). For DWI, Accel-DLR demonstrated significantly higher overall image quality scores (4.47±0.12 vs. 3.29±0.25; p

Förderung

  • Korea Health Industry Development Institute
  • Ministry of Health and Welfare
  • Ministry of Trade, Industry and Energy

Zitieren

APA

Oh, H. S., Jung, Y. H., Joo, B., Park, M., Suh, S. H., Seo, K., Lee, K., & Ahn, S. J. (2026). A Transitional Study for Clinical Implementation of Deep Learning-Accelerated Brain MRI: DWI, FLAIR, and SWI in a Healthy Cohort. Journal of Neurosonology and Neuroimaging, 18(1), 16-25. https://doi.org/10.31728/jnn.2026.00179

Vancouver

Oh HS, Jung YH, Joo B, Park M, Suh SH, Seo K, et al. A Transitional Study for Clinical Implementation of Deep Learning-Accelerated Brain MRI: DWI, FLAIR, and SWI in a Healthy Cohort. Journal of Neurosonology and Neuroimaging. 2026;18(1):16-25. doi:10.31728/jnn.2026.00179

BibTeX
@article{Oh2026,
  author = {Oh, Hee Sang and Jung, Yo Han and Joo, Bio and Park, Mina and Suh, Sang Hyun and Seo, Kwon-Duk and Lee, Kyung-Yul and Ahn, Sung Jun},
  title = {A Transitional Study for Clinical Implementation of Deep Learning-Accelerated Brain MRI: DWI, FLAIR, and SWI in a Healthy Cohort},
  journal = {Journal of Neurosonology and Neuroimaging},
  year = {2026},
  volume = {18},
  number = {1},
  pages = {16--25},
  doi = {10.31728/jnn.2026.00179}
}
Kostenlos starten →