Validation of a novel artificial intelligence model (SpinePose) to automatically and accurately predict spinopelvic parameters using scoliosis radiographs in an external cohort
Neurosurgical Focus · 2025
DOI: 10.3171/2025.3.focus2574 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Neurosurgical Focus, 2025. Verfasst von Rushikesh S Joshi und 12 weiteren Autor:innen. Beteiligte Einrichtung: 1Department of Neurological Surgery, University of Michigan, Ann Arbor. Hauptthemen laut MEDLINE: Scoliosis, Artificial Intelligence, Spine, Pelvis. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 62 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE SpinePose was developed in 2024 as a novel artificial intelligence (AI) tool to automatically predict spinopelvic parameters with high accuracy and without the need for manual entry. The authors’ published results demonstrated excellent performance comparable to a fellowship-trained spine surgeon with more than 15 years of experience. To date, there have not been any studies that have externally validated the performance of AI-based spinopelvic parameter measurement tools on data acquired from other institutions. To assess the generalizability of SpinePose, the authors report its performance on an external set of heterogeneous whole-spine scoliosis radiographs obtained from an outside institution. METHODS SpinePose was trained/validated on a dataset of 761 sagittal whole-spine scoliosis radiographs from a single institution, with expert-level performance on both whole-spine and lumbosacral radiographs. In this study, the existing SpinePose model was used for inference on a new set of 49 whole-spine radiographs acquired at a tertiary academic hospital located out of state. Externally acquired radiographs represented a diverse set of images, incorporating patients who had undergone instrumentation and those who had not, and a wide variety of fusion constructs including complex deformity patients. Predicted measures included sagittal vertical axis (SVA), pelvic tilt (PT), pelvic incidence (PI), lumbar lordosis (LL), and T1–pelvic angle (T1PA). Predicted parameter values relative to ground-truth manual annotations were calculated to determine the model’s accuracy. RESULTS Of the 49 images, 35 (71.4%) had instrumentation compared with 51.0% and 57.5% in the original SpinePose training and testing sets, respectively. All 5 parameters in the external dataset were significantly different at baseline compared with the original test set (p < 0.01). SpinePose accurately predicted all 5 spinopelvic parameters without any statistically significant differences: SVA, 50.7 mm vs 52.3 mm (p = 0.85); PT, 27.6° vs 30.5° (p = 0.24); PI, 58.0° vs 61.8° (p = 0.17); LL, 40.4° vs 42.4° (p = 0.77); and T1PA, 24.8° vs 28.0° (p = 0.21) when comparing ground truth annotations with predicted values. CONCLUSIONS SpinePose was able to accurately predict spinopelvic parameters on an external validation cohort that was generated independently from the images on which the model was trained and validated. This highlights the generalizability of SpinePose to be implemented on novel images from other institutions and geographic settings with high accuracy and minimal preprocessing. The implementation of AI tools more broadly will help standardize our ability to both deliver and provide spine care and assist with surgical treatment and management of spine patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- 1Department of Neurological Surgery, University of Michigan, Ann Arbor.
- 2School of Medicine, University of Michigan, Ann Arbor.
- 3Department of Computational Medicine and Bioinformatics, University of Michigan, Ann Arbor, Michigan.
- 4Department of Orthopedic Surgery, University of Minnesota, Minneapolis, Minnesota.
- 5Department of Radiology, University of Michigan, Ann Arbor, Michigan; and.
- 6Department of Neurosurgery, Semmes Murphey Neurologic and Spine Institute, University of Tennessee, Memphis, Tennessee.
Zitieren
APA
Joshi, R. S., Harake, E. S., Jiang, C., Haselhuhn, J. J., Linzey, J. R., Jones, J. C., Zaki, M. M., Odland, K., Wilseck, Z., Joseph, J. R., Polly, D. W., Hollon, T. C., & Park, P. (2025). Validation of a novel artificial intelligence model (SpinePose) to automatically and accurately predict spinopelvic parameters using scoliosis radiographs in an external cohort. Neurosurgical Focus. https://doi.org/10.3171/2025.3.focus2574
Vancouver
Joshi RS, Harake ES, Jiang C, Haselhuhn JJ, Linzey JR, Jones JC, et al. Validation of a novel artificial intelligence model (SpinePose) to automatically and accurately predict spinopelvic parameters using scoliosis radiographs in an external cohort. Neurosurgical Focus. 2025. doi:10.3171/2025.3.focus2574
BibTeX
@article{Joshi2025,
author = {Joshi, Rushikesh S and Harake, Edward S and Jiang, Cheng and Haselhuhn, Jason J and Linzey, Joseph R and Jones, Jaes C and Zaki, Mark M and Odland, Kari and Wilseck, Zachary and Joseph, Jacob R and Polly, David W and Hollon, Todd C and Park, Paul},
title = {Validation of a novel artificial intelligence model (SpinePose) to automatically and accurately predict spinopelvic parameters using scoliosis radiographs in an external cohort},
journal = {Neurosurgical Focus},
year = {2025},
doi = {10.3171/2025.3.focus2574}
}