EUVIMEDEUVIMED entdecken
Open Access

Implanting microelectrode arrays in the bottom of the central sulcus targeting somatosensory area 3a for restoration of proprioception

Tyler R Johnson, Sarah Moralle, Ziling Luo, Dawn M Taylor

Neurosurgical Focus · 01.02.2026 · 60 (2) · E8

DOI: 10.3171/2025.11.focus25916 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Neurosurgical Focus, erschienen am 01.02.2026. Verfasst von Tyler R Johnson und 3 weiteren Autor:innen. Beteiligte Einrichtung: 1Department of Neurosciences, Cleveland Clinic, Cleveland. Hauptthemen laut MEDLINE: Electrodes, Implanted, Proprioception, Somatosensory Cortex, Brain-Computer Interfaces. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE The long-term goal of this work is to develop a sensorimotor brain-machine interface (BMI) in which intended movements are decoded from the motor cortex and proprioceptive feedback is delivered via intracortical microstimulation of Brodmann’s area 3a. A vital step toward this goal is to demonstrate in rhesus macaques a novel surgical approach for the precise and safe implantation of custom-length microelectrode arrays into area 3a at the bottom of the central sulcus. METHODS Preoperative planning combined high-resolution 7-T MR and CT imaging to generate 3D models of the cortices of 2 subjects. These models were used to fabricate 3D-printed skull replicas and to define a stereotactic trajectory that provided the shortest perpendicular path to the base of the central sulcus, where Brodmann’s area 3a resides. Custom variable-length microwire electrode arrays were designed to span this target region. The flexibility of the microwires precluded the standard impact-insertion approach used with stiffer electrodes. Therefore, a custom vacuum-powered microdrive holder that moved with the pulsating brain was developed to maintain electrode orientation and to allow slow, controlled insertion along the planned trajectory. After implantation, the craniotomy was closed, and a skull-mounted recording chamber was secured. Postoperative verification of array placement was performed using CT imaging and neural recordings. RESULTS In both animals, imaging revealed that the base of the central sulcus was positioned anterior to its dorsal opening, making a precentral implant trajectory the shortest and most direct path to the bottom of the central sulcus. The integrated imaging and 3D modeling approach enabled accurate stereotactic placement of custom microelectrode arrays using the novel vacuum-assisted microdrive, as confirmed by postoperative CT imaging. Both surgical procedures were completed without complication, and isolatable neuronal spikes were recorded from multiple channels in each subject. In both animals, neural activity was modulated by passive movements of the arm. CONCLUSIONS Intracortical microelectrode implants for BMI applications have traditionally been limited to short (1.5-mm) electrodes targeting cortical sites exposed on the brain surface. The surgical methodology described here enables safe and accurate implantation of custom-length arrays into deep sulcal targets such as Brodmann’s area 3a. By expanding access to previously inaccessible cortical regions, this approach broadens the potential neural information available for future BMI applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electrodes, ImplantedProprioceptionSomatosensory CortexBrain-Computer InterfacesAnimalsMicroelectrodesMacaca mulattaMagnetic Resonance ImagingMale

Stichwörter der Autor:innen

BMIBrodmann’s area 3abrain-machine interfacemicrowire electrode arrayneurosurgerynonhuman primatestereotactic targeting

Autor:innen und Institutionen

  • 1Department of Neurosciences, Cleveland Clinic, Cleveland.
  • 2Department of Biomedical Engineering, Case Western Reserve University, Cleveland; and.
  • 3Cleveland Functional Electrical Stimulation Center of Excellence, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio.

Förderung

  • NINDS NIH HHS

Zitieren

APA

Johnson, T. R., Moralle, S., Luo, Z., & Taylor, D. M. (2026). Implanting microelectrode arrays in the bottom of the central sulcus targeting somatosensory area 3a for restoration of proprioception. Neurosurgical Focus, 60(2), E8. https://doi.org/10.3171/2025.11.focus25916

Vancouver

Johnson TR, Moralle S, Luo Z, Taylor DM. Implanting microelectrode arrays in the bottom of the central sulcus targeting somatosensory area 3a for restoration of proprioception. Neurosurgical Focus. 2026;60(2):E8. doi:10.3171/2025.11.focus25916

BibTeX
@article{Johnson2026,
  author = {Johnson, Tyler R and Moralle, Sarah and Luo, Ziling and Taylor, Dawn M},
  title = {Implanting microelectrode arrays in the bottom of the central sulcus targeting somatosensory area 3a for restoration of proprioception},
  journal = {Neurosurgical Focus},
  year = {2026},
  volume = {60},
  number = {2},
  pages = {E8},
  doi = {10.3171/2025.11.focus25916}
}
Kostenlos starten →