EUVIMEDEUVIMED entdecken
Crossref

Morphometric analysis of the spinal cord in patients undergoing posterior vertebral column subtraction osteotomy for recurrent tethered cord syndrome

Kelly Jiang, Carly Weber-Levine, Vikas N Vattipally, A Daniel Davidar, Max Kerensky, Andrew M Hersh, Denis Routkevitch, Brendan Judy, Kimberly Ashayeri, Daniel Lubelski, Mari Groves, Khalil Husari und 1 weitere

Journal of Neurosurgery: Spine · 2024

DOI: 10.3171/2024.6.spine24176 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neurosurgery: Spine, 2024. Verfasst von Kelly Jiang und 12 weiteren Autor:innen. Beteiligte Einrichtung: Departments of1Neurosurgery and. Hauptthemen laut MEDLINE: Neural Tube Defects, Osteotomy, Spinal Cord, Lumbar Vertebrae. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE In posterior vertebral column subtraction osteotomy (PVCSO), a section of a thoracic or lumbar vertebra and the adjacent disc are resected to shorten the spinal column, aiming to permanently alleviate tension on the spinal cord in patients with recurrent tethered cord syndrome (TCS). The effects of this procedure on the spinal cord are not well characterized. This study investigated morphometric changes in the cord following PVCSO and assessed associated clinical outcomes in patients with recurrent TCS. METHODS A retrospective review of patients with recurrent TCS undergoing PVCSO with robotic assistance at the authors’ tertiary care institution between 2019 and 2023 was performed. Clinical data were recorded from electronic medical records, and morphometric measurements, including T12–L2 sagittal height, intradural diameter, and the diameters, area, eccentricity, and positioning of the spinal cord, were collected from MRI. Spinal cord dimensions including anteroposterior and lateral diameters, area, eccentricity, positioning, and intradural diameter were compared before and after surgery. RESULTS Six patients were included in this study. At 6-week follow-up, all patients had improvement on lower-extremity motor function examinations, 40% had improvement on lower-extremity sensory function examinations, and 83% had improved self-reported pain. Bladder and bowel incontinence were improved in 50% and 60%, respectively. PVCSO reduced the height of the spinal column by a mean of 18.1 ± 5.2 mm. PVCSO increased the mean spinal cord anteroposterior diameter by 0.8 ± 0.5 mm at T12 (p = 0.03) and the mean area by 0.4 ± 0.3 mm 2 at T12 (p = 0.03). The mean eccentricity of the spinal cord decreased by 0.15 ± 0.15 at L1 (p = 0.05), indicating that the spinal cord became more circular after surgery. No major complications were reported, although 1 patient experienced atelectasis and pulmonary embolism postoperatively. CONCLUSIONS This study provides novel insights into the morphometric changes induced by PVCSO and their correlation with clinical outcomes in patients with TCS. The procedure effectively increased spinal cord dimensions, alleviating tension and offering potential benefits in symptom relief. The study underscores the need for objective metrics to guide surgical decision-making and enhance the long-term success of PVCSO in the management of TCS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Neural Tube DefectsOsteotomySpinal CordLumbar VertebraeThoracic VertebraeHumansFemaleMaleRetrospective StudiesAdultTreatment OutcomeYoung AdultAdolescentMagnetic Resonance ImagingRecurrence

Stichwörter der Autor:innen

congenitallipomyelomeningoceleposterior vertebral column subtraction osteotomytethered cord syndrome

Autor:innen und Institutionen

  • Departments of1Neurosurgery and.
  • 2Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland.
  • 3Neurology, Johns Hopkins Hospital, Baltimore; and.

Zitieren

APA

Jiang, K., Weber-Levine, C., Vattipally, V. N., Davidar, A. D., Kerensky, M., Hersh, A. M., Routkevitch, D., Judy, B., Ashayeri, K., Lubelski, D., Groves, M., Husari, K., & Theodore, N. (2024). Morphometric analysis of the spinal cord in patients undergoing posterior vertebral column subtraction osteotomy for recurrent tethered cord syndrome. Journal of Neurosurgery: Spine. https://doi.org/10.3171/2024.6.spine24176

Vancouver

Jiang K, Weber-Levine C, Vattipally VN, Davidar AD, Kerensky M, Hersh AM, et al. Morphometric analysis of the spinal cord in patients undergoing posterior vertebral column subtraction osteotomy for recurrent tethered cord syndrome. Journal of Neurosurgery: Spine. 2024. doi:10.3171/2024.6.spine24176

BibTeX
@article{Jiang2024,
  author = {Jiang, Kelly and Weber-Levine, Carly and Vattipally, Vikas N and Davidar, A Daniel and Kerensky, Max and Hersh, Andrew M and Routkevitch, Denis and Judy, Brendan and Ashayeri, Kimberly and Lubelski, Daniel and Groves, Mari and Husari, Khalil and Theodore, Nicholas},
  title = {Morphometric analysis of the spinal cord in patients undergoing posterior vertebral column subtraction osteotomy for recurrent tethered cord syndrome},
  journal = {Journal of Neurosurgery: Spine},
  year = {2024},
  doi = {10.3171/2024.6.spine24176}
}
Kostenlos starten →