EUVIMEDEUVIMED entdecken
MetaanalyseSystematische Übersicht

Robot-assisted percutaneous pedicle screw placement accuracy compared with alternative guidance in lateral single-position surgery: a systematic review and meta-analysis

Neal A Patel, Cathleen C Kuo, Zach Pennington, Nolan J Brown, Julian Gendreau, Rohin Singh, Shane Shahrestani, Candler Boyett, Luis Daniel Diaz-Aguilar, Martin H Pham

Journal of Neurosurgery: Spine · 2023

DOI: 10.3171/2023.3.spine2329 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift Journal of Neurosurgery: Spine, 2023. Verfasst von Neal A Patel und 9 weiteren Autor:innen. Beteiligte Einrichtung: 1School of Medicine, Mercer University, Columbus, Georgia. Hauptthemen laut MEDLINE: Pedicle Screws, Surgery, Computer-Assisted, Robotics, Spinal Fusion. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 47 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE While single-position surgery (SPS) eliminates the need for patient repositioning, the placement of screws in the unconventional lateral position poses unique challenges related to asymmetry relative to the surgical table. Use of robotic guidance or intraoperative navigation can help to overcome this. The aim of this study was to compare the relative accuracies offered by these various navigation modalities for pedicle screws placed in lateral SPS. METHODS According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, the PubMed/Medline, Embase, and Cochrane Library databases were queried for studies reporting pedicle screw placement accuracy using fluoroscopic, CT-navigated, O-arm, or robotic guidance in lateral SPS, and a systematic review and meta-analysis was performed. Included studies all compared evaluated screw placement accuracy in lateral SPS using a single navigation method. Quality assessment was performed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system; risk of bias was assessed using the Newcastle-Ottawa Scale and the Joanna Briggs Institute checklist. The primary outcome, rate of pedicle screw breach, was analyzed using random-effects meta-analysis. RESULTS Eleven studies were included comprising 548 patients who underwent the placement of instrumentation with 2488 screws. For the fluoroscopic, CT-navigated, O-arm, and robotic guidance cohorts, there were 3, 2, 3, and 3 studies, respectively. Breach rates by modality were as follows: fluoroscopic guidance (6.6%), CT navigation (4.7%), O-arm (3.9%), and robotic guidance (3.9%). Random-effects meta-analysis showed a significant difference between studies, with an overall breach rate of 4.9% (95% CI 3.1%–7.5%; p < 0.001); however, testing for subgroup differences failed to show a significant difference between guidance modalities (Q M = 0.69, df = 3; p = 0.88). Heterogeneity between studies was significant (I 2 = 79.0%, τ 2 = 0.41, χ 2 = 47.65, df = 10; p < 0.001). CONCLUSIONS Robotic guidance of screws is noninferior to alternative guidance modalities in lateral SPS; however, additional prospective studies directly comparing different guidance types are merited.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pedicle ScrewsSurgery, Computer-AssistedRoboticsSpinal FusionHumansImaging, Three-DimensionalProspective StudiesTomography, X-Ray ComputedRetrospective StudiesLumbar Vertebrae

Stichwörter der Autor:innen

lumbarmeta-analysispercutaneous pedicle screwrobot-assistedscrew accuracysingle-position surgery

Autor:innen und Institutionen

  • 1School of Medicine, Mercer University, Columbus, Georgia.
  • 2Department of Neurosurgery, University at Buffalo, New York.
  • 3Department of Neurosurgery, Mayo Clinic, Rochester, Minnesota.
  • 4Department of Neurosurgery, University of California, Irvine, Orange, California.
  • 5Department of Biomedical Engineering, Johns Hopkins Whiting School of Engineering, Baltimore, Maryland.
  • 6Mayo Clinic Alix School of Medicine, Scottsdale, Arizona.

Zitieren

APA

Patel, N. A., Kuo, C. C., Pennington, Z., Brown, N. J., Gendreau, J., Singh, R., Shahrestani, S., Boyett, C., Diaz-Aguilar, L. D., & Pham, M. H. (2023). Robot-assisted percutaneous pedicle screw placement accuracy compared with alternative guidance in lateral single-position surgery: a systematic review and meta-analysis. Journal of Neurosurgery: Spine. https://doi.org/10.3171/2023.3.spine2329

Vancouver

Patel NA, Kuo CC, Pennington Z, Brown NJ, Gendreau J, Singh R, et al. Robot-assisted percutaneous pedicle screw placement accuracy compared with alternative guidance in lateral single-position surgery: a systematic review and meta-analysis. Journal of Neurosurgery: Spine. 2023. doi:10.3171/2023.3.spine2329

BibTeX
@article{Patel2023,
  author = {Patel, Neal A and Kuo, Cathleen C and Pennington, Zach and Brown, Nolan J and Gendreau, Julian and Singh, Rohin and Shahrestani, Shane and Boyett, Candler and Diaz-Aguilar, Luis Daniel and Pham, Martin H},
  title = {Robot-assisted percutaneous pedicle screw placement accuracy compared with alternative guidance in lateral single-position surgery: a systematic review and meta-analysis},
  journal = {Journal of Neurosurgery: Spine},
  year = {2023},
  doi = {10.3171/2023.3.spine2329}
}
Kostenlos starten →