Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neurosurgery: Pediatrics, 2023. Verfasst von Nikolaos Tachatos und 5 weiteren Autor:innen. Beteiligte Einrichtung: 1Department of Mechanical and Process Engineering, Product Development Group Zurich, ETH Zurich. Hauptthemen laut MEDLINE: Ventriculoperitoneal Shunt, Hydrocephalus. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE Infants and small children face changing boundary conditions when treated with a ventriculoperitoneal shunt (VPS) for hydrocephalus. There are no systematic data describing shunt drainage behavior and changes over time in a growing child. Using a child-adapted patient simulator, the authors investigated the drainage behaviors of fixed differential pressure (DP) valves and adjustable valves with devices for preventing overdrainage in children of different ages. METHODS Three miniNAV DP valves with a 10–cm H 2 O medium-pressure setting (MN10) and three adjustable proGAV2.0 valves with a 25–cm H 2 O gravitational unit (GU) at low 5–cm H 2 O opening pressure (PG5) and medium 10–cm H 2 O opening pressure (PG10) settings were each investigated with a hardware-in-the-loop test bed. This test bed consisted of a posture motion mechanism and two pressure compartments that mimicked intracranial and abdominal pressures and was used to test the VPS under realistic in vitro conditions. Body orientation and length were physically set according to the child’s age. The software simulated the physiological situations of children aged 1, 5, and 10 years. All valves were tested according to these specifications, with 5 runs for 1 hour each in the horizontal, vertical, and horizontal positions. Intracranial pressure (ICP) and VPS flow were measured, and the respective cerebrospinal fluid volume changes and ICP set value were computed. RESULTS The drainage parameters increased with age in all valves in the vertical position, with that of MN10 being pronounced in the 1-year-old simulation. The GU values in PG5 and PG10 substantially reduced drainage compared with MN10. PG10 prevented drainage in the 1-year-old and 5-year-old setups, but there was some drainage at physiological ICP in the 10-year-old setup. In contrast, MN10 produced the largest decreases in ICP across all ages and positions, and overdrainage resulted in insufficient ICP recovery in the subsequent horizontal position. ICP levels were mostly constant with PG10 at all ages. CONCLUSIONS This study shows that unprotected DP valves may lead to overdrainage in infants, whereas low-pressure GU valves can prevent overdrainage through 5 years and medium-pressure GU valves admit physiological ICP through at least 10 years. Therefore, devices for preventing overdrainage should be included in the first implanted shunt, and opening pressure should be adjusted as the child grows.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ventriculoperitoneal ShuntHydrocephalusInfantHumansChildCerebrospinal Fluid ShuntsIntracranial PressureDrainageEquipment Design

Stichwörter der Autor:innen

differential pressure valvehardware-in-the-loop testingoverdrainage syndromepediatric hydrocephalusventriculoperitoneal shunt

Autor:innen und Institutionen

  • 1Department of Mechanical and Process Engineering, Product Development Group Zurich, ETH Zurich.
  • 2Department of Neurosurgery, University Hospital Zurich.
  • 3Translational Research Center, University Hospital of Psychiatry and Psychotherapy, University of Bern, Switzerland.
  • 4Department of Neurosurgery, Section of Pediatric Neurosurgery, University Hospital Tübingen, Germany; and.
  • 5Department of Mechanical and Process Engineering, Institute for Dynamic Systems and Control, ETH Zurich, Switzerland.

Zitieren

APA

Tachatos, N., Fernandes Dias, S., Jehli, E., Lübben, D., Schuhmann, M. U., & Schmid Daners, M. (2023). Effect of antisiphon devices on ventriculoperitoneal shunt drainage dynamics in growing children. Journal of Neurosurgery: Pediatrics. https://doi.org/10.3171/2023.2.peds22515

Vancouver

Tachatos N, Fernandes Dias S, Jehli E, Lübben D, Schuhmann MU, Schmid Daners M. Effect of antisiphon devices on ventriculoperitoneal shunt drainage dynamics in growing children. Journal of Neurosurgery: Pediatrics. 2023. doi:10.3171/2023.2.peds22515

BibTeX
@article{Tachatos2023,
  author = {Tachatos, Nikolaos and Fernandes Dias, Sandra and Jehli, Elisabeth and Lübben, Dennis and Schuhmann, Martin Ulrich and Schmid Daners, Marianne},
  title = {Effect of antisiphon devices on ventriculoperitoneal shunt drainage dynamics in growing children},
  journal = {Journal of Neurosurgery: Pediatrics},
  year = {2023},
  doi = {10.3171/2023.2.peds22515}
}