EUVIMEDEUVIMED entdecken
MetaanalyseSystematische Übersicht

Flow diversion using the Pipeline embolization device for intracranial and extracranial pseudoaneurysms: a systematic review and meta-analysis of the literature

Elena Greco, Jorge Rios-Zermeno, Abdul Karim Ghaith, Umme Habiba Faisal, Anshit Goyal, Oluwaseun O Akinduro, Samir Kashyap, David A Miller, Stephen P Graepel, Mohamad Bydon, Erik H Middlebrooks, Sukhwinder S Sandhu und 1 weitere

Neurosurgical Focus · 2023

DOI: 10.3171/2023.2.focus22644 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift Neurosurgical Focus, 2023. Verfasst von Elena Greco und 12 weiteren Autor:innen. Beteiligte Einrichtung: Departments of1Neurological Surgery and. Hauptthemen laut MEDLINE: Aneurysm, False, Intracranial Aneurysm, Embolization, Therapeutic. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 46 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE Pseudoaneurysms (PSAs) are complex vascular lesions. Flow diversion has been proposed as an alternative treatment to parent artery occlusion that preserves laminar flow. The authors of the present study investigated the safety and short-term (< 1 year) and long-term (≥ 1 year) aneurysm occlusion rates following the treatment of intracranial and extracranial PSAs using the Pipeline embolization device (PED). METHODS An electronic database search for full-text English-language articles in Ovid MEDLINE and Epub Ahead of Print, Ovid Embase, Ovid Cochrane Central Register of Controlled Trials, Ovid Cochrane Database of Systematic Reviews, and Scopus was conducted following the PRISMA guidelines. Studies of any design including at least 4 patients with intracranial or extracranial PSAs treated using a PED were included in this analysis. The primary outcome of interest was the rate of peri- and postprocedural complications. Secondarily, the authors analyzed the incidence of complete aneurysm occlusion. RESULTS A total of 90 patients with 96 PSAs across 9 studies were included. The mean age was 38.2 (SD 15.14) years, and 37.8% of the patients were women. The mean PSA size was 4.9 mm. Most PSAs were unruptured, and the most common etiology was trauma (n = 32, 35.5%), followed by spontaneous formation (n = 21, 23.3%) and iatrogenic injury (n = 19, 21.1%). Among the 51 (53.1%) intracranial and 45 (46.9%) extracranial PSAs were 19 (19.8%) dissecting PSAs. Sixty-six (77.6%) PSAs were in the internal carotid artery and 10 (11.8%) in the vertebral artery. Thirty-three (34.4%) PSAs were treated with ≥ 2 devices, and 8 (8.3%) underwent adjunctive coiling. The mean clinical and angiographic follow-up durations were 10.7 and 12.9 months, respectively. The short-term (< 1 year) and long-term (≥ 1 year) complete occlusion rates were 79% (95% CI 66%–88%, p = 0.82) and 84% (95% CI 70%–92%, p = 0.95), respectively. Complication rates were 8% for iatrogenic dissection (95% CI 3%–16%, p = 0.94), 10% for silent thromboembolism (95% CI 5%–21%, p = 0.77), and 12% for symptomatic thromboembolism (95% CI 6%–23%, p = 0.48). No treatment-related hemorrhage was observed. The overall mortality rate at the last follow-up was 14%. CONCLUSIONS The complete occlusion rate for PSAs treated with the PED was high and increased over time. Although postprocedural complications and mortality were not insignificant, flow diversion represents a reasonably safe option for managing these complex lesions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aneurysm, FalseIntracranial AneurysmEmbolization, TherapeuticHumansFemaleAdultMaleTreatment OutcomeCerebral AngiographyIatrogenic DiseaseRetrospective StudiesStents

Stichwörter der Autor:innen

Pipeline embolization deviceflow diversionlong-term outcomespseudoaneurysms

Autor:innen und Institutionen

  • Departments of1Neurological Surgery and.
  • 2Radiology, Mayo Clinic, Jacksonville, Florida.
  • 3Department of Neurological Surgery, Instituto Nacional de Neurología y Neurocirugía, Mexico City, Mexico.
  • 4Mayo Clinic Neuro-Informatics Laboratory, Mayo Clinic, Rochester, Minnesota.
  • 5Department of Neurological Surgery, Mayo Clinic, Rochester, Minnesota.
  • 6All India Institute of Medical Sciences, Kalyani, West Bengal, India; and.

Zitieren

APA

Greco, E., Rios-Zermeno, J., Ghaith, A. K., Faisal, U. H., Goyal, A., Akinduro, O. O., Kashyap, S., Miller, D. A., Graepel, S. P., Bydon, M., Middlebrooks, E. H., Sandhu, S. S., & Tawk, R. G. (2023). Flow diversion using the Pipeline embolization device for intracranial and extracranial pseudoaneurysms: a systematic review and meta-analysis of the literature. Neurosurgical Focus. https://doi.org/10.3171/2023.2.focus22644

Vancouver

Greco E, Rios-Zermeno J, Ghaith AK, Faisal UH, Goyal A, Akinduro OO, et al. Flow diversion using the Pipeline embolization device for intracranial and extracranial pseudoaneurysms: a systematic review and meta-analysis of the literature. Neurosurgical Focus. 2023. doi:10.3171/2023.2.focus22644

BibTeX
@article{Greco2023,
  author = {Greco, Elena and Rios-Zermeno, Jorge and Ghaith, Abdul Karim and Faisal, Umme Habiba and Goyal, Anshit and Akinduro, Oluwaseun O and Kashyap, Samir and Miller, David A and Graepel, Stephen P and Bydon, Mohamad and Middlebrooks, Erik H and Sandhu, Sukhwinder S and Tawk, Rabih G},
  title = {Flow diversion using the Pipeline embolization device for intracranial and extracranial pseudoaneurysms: a systematic review and meta-analysis of the literature},
  journal = {Neurosurgical Focus},
  year = {2023},
  doi = {10.3171/2023.2.focus22644}
}
Kostenlos starten →