EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quantification of lactobionate using ion-exclusion high-performance liquid chromatography

Yufeng Lin, Usman Amin, C K Yeung, Haotian Zheng

JDS Communications · 2026-11 · 7 (6) · 731-736

DOI: 10.3168/jdsc.2026-1136 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JDS Communications, 2026-11. Verfasst von Yufeng Lin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Food Rheology Laboratory, Department of Food, Bioprocessing and Nutrition Sciences, North Carolina State University, Raleigh, NC 27695. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: California Dairy Research Foundation, National Institute of Food and Agriculture.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Lactobionic acid (LBA) and calcium lactobionate (Ca-LBN) are emerging value-added ingredients that can be manufactured from cheese whey permeate streams. Reliable analytical methods for quantifying the contents of LBA or lactobionate (LBN) in processed products derived from dairy permeates are still scarce. This study established a rapid ion-exclusion high-performance liquid chromatography (IE-HPLC) method for quantifying LBN and lactose in a product slurry obtained from enzymatic lactose oxidation trials for manufacturing Ca-LBN from cheese whey permeate. Chromatographic separation was achieved using an ion exclusion column containing fully sulfonated resin with an aqueous H2SO4 mobile phase (0.45 mM) at 0.5 mL/min and 75°C. The chromatogram analysis was assisted by the Gaussian deconvolution method for resolving overlapping peaks between the LBA anion and lactose. Standard curves of LBA and lactose standards were prepared within the same concentration range of 0.5 to 10 mM. The IE-HPLC method was able to quantify LBN anion presence in the Ca-LBN slurry as processed from cheese whey permeate through the mentioned enzymatic oxidation process. According to the IE-HPLC analysis, the LBN anion content in the Ca-LBN slurry was characterized as ∼755 mM; this was equivalent to an 86% lactose-LBN molar conversion rate (given the original lactose substrate content was 300 g/L ≈ 877 mM). This was an underestimation of ∼13% compared with the previously reported conversion rate (∼99%) in another publication for the same sample, in which the conversion rate was calculated based on Ca(OH)2 consumption during pH-stat auto-titration in response to produced LBN anions. Such a deviation in LBN quantification between the IE-HPLC method used in the present work and the pH-stat method used in the other work suggested that the IE-HPLC analysis might result in underestimation of the absolute quantity of LBN or LBA anions. This was confirmed by the spike recovery experiment. The Ca-LBN sample was spiked with an additional LBA standard, and the spiked Ca-LBN did not show an additional peak in the chromatogram after Gaussian deconvolution peak fitting, validating the LBN anion peak identification. Moreover, the spike recovery was ∼89%, confirming that IE-HPLC may underestimate LBN or LBA in processed dairy permeate. This documented IE-HPLC method can be used by industry, including LBN manufacturers and LBN ingredient users, for quality control and for quantity validation purposes.

Autor:innen und Institutionen

  • Food Rheology Laboratory, Department of Food, Bioprocessing and Nutrition Sciences, North Carolina State University, Raleigh, NC 27695.
  • Southeast Dairy Foods Research Center, North Carolina State University, Raleigh, NC 27695.
  • Animal Science Department, California Polytechnic State University, San Luis Obispo, CA 93407.

Förderung

  • California Dairy Research Foundation
  • National Institute of Food and Agriculture

Zitieren

APA

Lin, Y., Amin, U., Yeung, C. K., & Zheng, H. (2026). Quantification of lactobionate using ion-exclusion high-performance liquid chromatography. JDS Communications, 7(6), 731-736. https://doi.org/10.3168/jdsc.2026-1136

Vancouver

Lin Y, Amin U, Yeung CK, Zheng H. Quantification of lactobionate using ion-exclusion high-performance liquid chromatography. JDS Communications. 2026;7(6):731-736. doi:10.3168/jdsc.2026-1136

BibTeX
@article{Lin2026,
  author = {Lin, Yufeng and Amin, Usman and Yeung, C K and Zheng, Haotian},
  title = {Quantification of lactobionate using ion-exclusion high-performance liquid chromatography},
  journal = {JDS Communications},
  year = {2026},
  volume = {7},
  number = {6},
  pages = {731--736},
  doi = {10.3168/jdsc.2026-1136}
}