Field validation of a commercial pasteurization system for heat-treating individual bags of bovine colostrum
JDS Communications · 2026-11 · 7 (6) · 968-973
DOI: 10.3168/jdsc.2026-1081 ↗Kurz gefasst
Fachartikel in der Zeitschrift JDS Communications, 2026-11. Verfasst von Sandra M Godden und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Population Medicine, University of Minnesota, St. Paul, MN 55108. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Zinpro, University of Minnesota, Iowa State University.
Abstract (Originalsprache)
Our primary objective was to evaluate the effects on IgG and bacteria concentrations of using a commercial pasteurizer system (Matilda Colostrum Pasteurizer and Warmer, DairyTech Inc., Windsor, CO) to heat-treat (HT) individual bags (3.8 L) of bovine colostrum, as compared with treating larger volumes of pooled colostrum (>57 L) in a vat pasteurizer. A secondary objective was to describe concentrations of IgG and bacteria in pre-HT versus post-HT colostrum, whether processed using the Matilda pasteurizer for small volumes or a vat pasteurizer system for large volumes. The study was conducted in summer 2024 on a commercial Midwest Holstein dairy. Each day, high quality (Brix >22%; estimated IgG >50 g/L) colostrum was selected and pooled to create a single unique batch (57-95 L [15-25 gallons; gal]), then transferred into the on-farm 144-L (30 gal) vat pasteurizer. After mixing well and collecting aseptic samples for later testing, 3.8 L were transferred from the pool into a 4-L single-use disposable bag (Perfect Udder [PU] bag system, DairyTech Inc.) which was then placed in a small commercial colostrum pasteurizer system (Matilda Pasteurizer and Warmer, DairyTech Inc.). The large pool and the single bag of colostrum were both then HT in the vat pasteurizer (VAT) and Matilda pasteurizer system (MAT), respectively, at 60°C (140°F) for 60 min. Following rapid cooling to 15.5°C (60°F), aseptic samples of post-HT colostrum were collected from both the VAT and MAT systems and frozen (-20°C) for later analysis. Pre-HT colostrum from the original fresh pool and post-HT colostrum collected from both the VAT and MAT pasteurizer systems were submitted for determination of IgG concentration (g/L) using an radial immunodiffusion assay, as well as aerobic culture to determine total plate count (TPC; cfu/mL) and total coliform count (TCC; cfu/mL). For objective 1, linear regression was used to evaluate if IgG, TPC, or TCC in post-HT colostrum varied by HT method (VAT vs. MAT). For objective 2, after stratifying the data by pasteurization method (VAT or MAT), linear regression was used to evaluate if IgG, TPC, or TCC concentrations were different between the pre- and post-HT samples. Results from 24 unique batches of colostrum showed no effect of HT method on mean (±SE) concentrations of IgG, TPC, or TCC in post-HT colostrum processed using the VAT method (82.7 ± 2.19 g/L; 2.64 ± 0.14 log10 cfu/mL; 0.20 ± 0.09 log10 cfu/mL, respectively) as compared with the MAT method (82.9 ± 2.19 g/L; 2.96 ± 0.14 log10 cfu/mL; 0.07 ± 0.09 log10 cfu/mL, respectively). Furthermore, whether processing a larger volume in the VAT system or a small volume in the MAT system, HT resulted in no reduction in IgG, but significantly reduced bacteria levels in post-HT (vs. pre-HT) colostrum. These results show that under the conditions of this study on a single commercial dairy farm, we achieved equally high quality and equally clean colostrum for calves, whether using a vat pasteurizer system for large volumes or using individual bags using the Matilda pasteurizer system for small volumes.
Autor:innen und Institutionen
- Department of Veterinary Population Medicine, University of Minnesota, St. Paul, MN 55108.
- Department of Dairy and Food Sciences, South Dakota State University, Brookings, SD 57007.
- CalfStart LLC, Altura, MN 55910.
- Superior Cattle Solutions, Madison, GA 30650.
Förderung
- Zinpro
- University of Minnesota
- Iowa State University
Zitieren
APA
Godden, S. M., Boelke, K., Smith, D., Karels, I., Schell, R., Geiger, A., & Knauer, W. A. (2026). Field validation of a commercial pasteurization system for heat-treating individual bags of bovine colostrum. JDS Communications, 7(6), 968-973. https://doi.org/10.3168/jdsc.2026-1081
Vancouver
Godden SM, Boelke K, Smith D, Karels I, Schell R, Geiger A, et al. Field validation of a commercial pasteurization system for heat-treating individual bags of bovine colostrum. JDS Communications. 2026;7(6):968-973. doi:10.3168/jdsc.2026-1081
BibTeX
@article{Godden2026,