EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Using an automated tail movement sensor device to predict calving time in dairy cows

S G Umaña Sedó, D L Renaud, J Morrison, D L Pearl, J F Mee, C B Winder

JDS Communications · 2024-07 · 5 (4) · 317-321

DOI: 10.3168/jdsc.2023-0445 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JDS Communications, 2024-07. Verfasst von S G Umaña Sedó und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Population Medicine, University of Guelph, Ontario, N1G2W1, Canada. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Dairy Farmers of Ontario, Ontario Ministry of Agriculture, Food and Rural Affairs.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to evaluate the effectiveness of an automated tail movement sensor device (Moocall; Bluebell, Dublin, Ireland) to predict time of calving in dairy cows. At a commercial dairy farm in southern Ontario, Moocall (MC) devices were attached with the device's strap, and an additional elastic wrap, to the tail of cows approximately 3 d before their expected calving date. The MC has 2 types of alarm, a high activity alarm in the previous hour (1HA), and a high activity alarm in the previous 2 h (2HA); these alarms were sent and registered to the MC software. The calving and close-up pens were video monitored to determine the exact time of the onset of stage II of calving (amniotic sac visible at the vulva) and the end of stage II of calving (total expulsion of the calf). A total of 49 cows were enrolled, but we excluded 13 animals from the analysis as they had 3 or more MC drops from the tail (n = 6), a swollen tail (n = 3), or the MC device was lost (n = 4); this left 36 cows. In total, the device dropped off 21 (42%) cows. The average number of alarms (1HA and 2HA) per cow before stage II of calving was 2.7 ± 2.3 (± standard error). The first alarm after fitting the device on the tail was used to determine the device's sensitivity and specificity. Depending on the interval before the onset of parturition (i.e., 2, 4, 8, 12 h) in which the alarm was triggered, sensitivity varied from 5% to 72% and specificity from 50% to 93%. The false positive rate varied between 6% and 50% depending on the interval from the alarm to the onset of parturition. The high false positive and device drop rates (despite the addition of the elastic wrap) may compromise the applicability of this sensor device in a commercial setting.

Autor:innen und Institutionen

  • Department of Population Medicine, University of Guelph, Ontario, N1G2W1, Canada.
  • Teagasc, Research Centre, Fermoy Co. Cork, P61 C997, Ireland.

Förderung

  • Dairy Farmers of Ontario
  • Ontario Ministry of Agriculture, Food and Rural Affairs

Zitieren

APA

Umaña Sedó, S. G., Renaud, D. L., Morrison, J., Pearl, D. L., Mee, J. F., & Winder, C. B. (2024). Using an automated tail movement sensor device to predict calving time in dairy cows. JDS Communications, 5(4), 317-321. https://doi.org/10.3168/jdsc.2023-0445

Vancouver

Umaña Sedó SG, Renaud DL, Morrison J, Pearl DL, Mee JF, Winder CB. Using an automated tail movement sensor device to predict calving time in dairy cows. JDS Communications. 2024;5(4):317-321. doi:10.3168/jdsc.2023-0445

BibTeX
@article{UmaaSed2024,
  author = {Umaña Sedó, S G and Renaud, D L and Morrison, J and Pearl, D L and Mee, J F and Winder, C B},
  title = {Using an automated tail movement sensor device to predict calving time in dairy cows},
  journal = {JDS Communications},
  year = {2024},
  volume = {5},
  number = {4},
  pages = {317--321},
  doi = {10.3168/jdsc.2023-0445}
}
Kostenlos starten →