EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Can water source and quality affect nutrient digestion?

David P Casper, Ishwary P Acharya

Journal of Dairy Science · 2025-09 · 108 (9) · 9595-9602

DOI: 10.3168/jds.2025-26434 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Dairy Science, 2025-09. Verfasst von David P Casper und 1 weiteren Autor:innen. Beteiligte Einrichtung: Casper's Calf Ranch, Freeport, IL 61032; Department of Animal Sciences, North Carolina A&T State University, Greensboro, NC 27411. Electronic address…. Hauptthemen laut MEDLINE: Digestion, Water, Water Quality. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study was conducted to evaluate the water source quality and a water treatment system to improve water quality for dairy cattle on the rate of ruminal fermentation and nutrient digestibility. One gram of dried ground TMR fed to lactating dairy cows was placed in a 50 μm Dacron bag, heat sealed, and then placed in a 500-mL Ankom gas fermentation bottle (GFB) containing ruminal fluid and treatment buffer to measure the rate and extent of ruminal nutrient digestion. Treatments were as follows: control, laboratory distilled water (DW); untreated ground water (UGW) from a local South Dakota dairy; treated ground water (TGW) using an H2O2 system; and municipal water (MW) supplied to the South Dakota State University Dairy Research and Teaching Farm (Brookings, SD). The experimental design was a randomized complete block design replicated using individual GFB as experimental units and replicated with 4 blocks. Ruminal fluid was collected from 2 ruminally cannulated cows fed the same TMR and strained through 4 layers of cheesecloth. Fifty milliliters of ruminal fluid mixed with 200 mL of Mould's buffer prepared from each water source were added to the GFB and incubated in a circulating water bath at 39°C. Gas measurements were collected every 5 min for 30 h. After 30 h, fermentation was arrested and the Dacron bags were removed, rinsed, and dried. The gas production rate was greater for DW compared to the other treatments (14.2%, 9.23%, 9.52%, and 9.66%/h for DW, UGW, TGW, and MW, respectively). Total VFA (mM) and acetate production were lower in DW compared with MW. The DM digestibility (82.0%, 81.6%, 80.8%, and 81.6%, for DW, UGW, TGW, and MW, respectively) tended to be lower for TGW water compared with DW water, with all other treatments being intermediate and similar. The NDF digestibility was similar for all treatments. Thus, water source and quality can affect the rate of ruminal microbial fermentation and nutrient digestion, which in turn can affect digestion estimates. However, the use of a water treatment system may still be a postruminal benefit to the animal beyond ruminal digestion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DigestionWaterWater QualityAnimalsCattleRumenFemaleFermentationAnimal FeedLactationDietNutrients

Stichwörter der Autor:innen

digestionqualityruminalwater

Substanzen

WaterNutrients

Autor:innen und Institutionen

  • Casper's Calf Ranch, Freeport, IL 61032; Department of Animal Sciences, North Carolina A&T State University, Greensboro, NC 27411. Electronic address: david.casper10@jcwifi.com.
  • Nutraferma Inc., North Sioux City, SD 57049.

Zitieren

APA

Casper, D. P., & Acharya, I. P. (2025). Can water source and quality affect nutrient digestion?. Journal of Dairy Science, 108(9), 9595-9602. https://doi.org/10.3168/jds.2025-26434

Vancouver

Casper DP, Acharya IP. Can water source and quality affect nutrient digestion?. Journal of Dairy Science. 2025;108(9):9595-9602. doi:10.3168/jds.2025-26434

BibTeX
@article{Casper2025,
  author = {Casper, David P and Acharya, Ishwary P},
  title = {Can water source and quality affect nutrient digestion?},
  journal = {Journal of Dairy Science},
  year = {2025},
  volume = {108},
  number = {9},
  pages = {9595--9602},
  doi = {10.3168/jds.2025-26434}
}
Kostenlos starten →