EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Modified paravertebral foramen screw trajectory for posterior cervical spine fixation: feasibility of computed tomographic evaluation

Sadaki Mitsuzawa, Eijiro Onishi, Satoshi Ota, Shinnosuke Yamashita, Yoshihiro Tsukamoto, Hisataka Takeuchi, Tadashi Yasuda, Shuichi Matsuda

Asian Spine Journal · 31.10.2026 · 20 (5) · 910-917

DOI: 10.31616/asj.2025.0487 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Asian Spine Journal, erschienen am 31.10.2026. Verfasst von Sadaki Mitsuzawa und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Kobe City Medical Center General Hospital, Kobe, Japan. sadakimitsuzawa@gmail.com. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Study Design: Retrospective cohort study.

Purpose

This study aimed to investigate bone quality and the trajectories of modified paravertebral foramen screw (mPVFS) on computed tomography (CT) images compared with those of PVFS and lateral mass screw (LMS).Overview of Literature: With increasing demand for cervical posterior fusion in aging populations, achieving optimal fixation remains challenging. The PVFS offers biomechanical stability with a safer trajectory than traditional pedicle screw and LMS. However, its efficacy in elderly patients with poor bone quality is a concern.

Methods

We analyzed the cervical CT images of 40 patients (10 patients per group), stratified by age and sex. Bone mineral density was assessed using CT attenuation values of the C5 vertebral body and lateral mass. We compared screw length, insertion area, and CT attenuation values along the screw trajectory across techniques.

Results

Bone quality decreased significantly with age, particularly in women. The mPVFS had a significantly longer trajectory than that of the PVFS (2.5–3.0 mm longer) and the LMS (1 mm longer) and a larger screw–bone contact area (1.2× that of PVFS, 1.4× that of LMS). CT attenuation values were higher along the mPVFS trajectory than along the PVFS and LMS trajectories. The differences were not consistently significant.Conclusions: mPVFS provides a biomechanical advantage by increasing screw length and contact area while targeting dense cancellous bone. mPVFS could safely accommodate screws that are 2.5–3.0 mm longer than conventional PVFS, irrespective of patient age or sex, which may be a potential clinical advantage. To validate its efficacy and long-term stability, further biomechanical and clinical studies are required.

Schlagwörter

Stichwörter der Autor:innen

Cervical spineComputed tomography attenuation valueLateral mass screwParavertebral foramen screwSurgical technique

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Kobe City Medical Center General Hospital, Kobe, Japan. sadakimitsuzawa@gmail.com.
  • Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan. sadakimitsuzawa@gmail.com.
  • Department of Orthopaedic Surgery, Kobe City Medical Center General Hospital, Kobe, Japan.
  • Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan.

Zitieren

APA

Mitsuzawa, S., Onishi, E., Ota, S., Yamashita, S., Tsukamoto, Y., Takeuchi, H., Yasuda, T., & Matsuda, S. (2026). Modified paravertebral foramen screw trajectory for posterior cervical spine fixation: feasibility of computed tomographic evaluation. Asian Spine Journal, 20(5), 910-917. https://doi.org/10.31616/asj.2025.0487

Vancouver

Mitsuzawa S, Onishi E, Ota S, Yamashita S, Tsukamoto Y, Takeuchi H, et al. Modified paravertebral foramen screw trajectory for posterior cervical spine fixation: feasibility of computed tomographic evaluation. Asian Spine Journal. 2026;20(5):910-917. doi:10.31616/asj.2025.0487

BibTeX
@article{Mitsuzawa2026,
  author = {Mitsuzawa, Sadaki and Onishi, Eijiro and Ota, Satoshi and Yamashita, Shinnosuke and Tsukamoto, Yoshihiro and Takeuchi, Hisataka and Yasuda, Tadashi and Matsuda, Shuichi},
  title = {Modified paravertebral foramen screw trajectory for posterior cervical spine fixation: feasibility of computed tomographic evaluation},
  journal = {Asian Spine Journal},
  year = {2026},
  volume = {20},
  number = {5},
  pages = {910--917},
  doi = {10.31616/asj.2025.0487}
}
Kostenlos starten →