EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Improving cross-axis wind turbine performance: A Lab-scale investigation of rotor size and blades number

Endang Achdi, Berkah Fajar Tamtomo Kiono, Sonny Handojo Winoto, Mochammmad Facta

Mechanical Engineering for Society and Industry · 2024

DOI: 10.31603/mesi.10837 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mechanical Engineering for Society and Industry, 2024. Verfasst von Endang Achdi und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Horizontal and vertical-axis wind turbines have long been used to generate electricity in open areas by utilizing horizontal wind flow. Under certain conditions, for example in multi-storey building areas, wind flows not only from horizontal but also vertical directions. Therefore, this research aims to develop a new turbine model known as a cross-axis to capture wind flow from horizontal and vertical directions around multi-storey buildings. Design, production, testing, and performance analysis are carried out in this project. The model is designed with a rotor diameter of 700 mm which has 5 vertical blades and 10 horizontal blades with a total height of 600 mm which is divided into two configurations, upper and lower. Performance analysis was carried out using a wind tunnel in a conditioned laboratory both in loaded and unloaded conditions. The output power of the wind turbine is measured using an electric dynamometer. The no-load test was applied to determine the time required to move from non-rotating to constant rotation at different speeds and horizontal blade angles. Meanwhile, the load test is used to determine the power coefficient at various speeds, horizontal blade pitch angles, and loads. The research results show that the time required to move from a non-rotating speed to a constant speed is influenced by the wind speed and the blade pitch angle. The power coefficient was also observed to be influenced by wind speed, blade pitch angle, and load. Furthermore, the shortest time to reach a constant rotation speed is around 20 seconds at a wind speed of 7.6 m/s and a blade pitch angle of 25°. The maximum power coefficient of the wind turbine was obtained at 5.2% at a wind speed of 7.6 m/s, blade pitch angle of 25°, and tip speed ratio of 0.5.

Zitieren

APA

Achdi, E., Kiono, B. F. T., Winoto, S. H., & Facta, M. (2024). Improving cross-axis wind turbine performance: A Lab-scale investigation of rotor size and blades number. Mechanical Engineering for Society and Industry. https://doi.org/10.31603/mesi.10837

Vancouver

Achdi E, Kiono BFT, Winoto SH, Facta M. Improving cross-axis wind turbine performance: A Lab-scale investigation of rotor size and blades number. Mechanical Engineering for Society and Industry. 2024. doi:10.31603/mesi.10837

BibTeX
@article{Achdi2024,
  author = {Achdi, Endang and Kiono, Berkah Fajar Tamtomo and Winoto, Sonny Handojo and Facta, Mochammmad},
  title = {Improving cross-axis wind turbine performance: A Lab-scale investigation of rotor size and blades number},
  journal = {Mechanical Engineering for Society and Industry},
  year = {2024},
  doi = {10.31603/mesi.10837}
}
Kostenlos starten →