Profil Sistem Energi Berbasis Saturasi Oksigen Otot (SmO₂) Atlet Bulutangkis Menggunakan Moxy Monitor untuk Pengkondisian Fisik
Gelanggang Olahraga: Jurnal Pendidikan Jasmani dan Olahraga (JPJO) · 20.07.2026 · 9 (5) · 2206-2217
DOI: 10.31539/r1wdn815 ↗Kurz gefasst
Fachartikel in der Zeitschrift Gelanggang Olahraga: Jurnal Pendidikan Jasmani dan Olahraga (JPJO), online erschienen am 20.07.2026. Verfasst von Irman Felisiana Miftahul Khoir und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
This study aims to analyze the muscle oxygen saturation (SmO₂) profile of badminton athletes using the Moxy Monitor, to examine its relationship with the aerobic and anaerobic energy systems, and to evaluate its potential as a basis for designing physical conditioning programs. This study used a quantitative approach with a correlational method involving 10 badminton athletes from PB Mutiara Cardinal Bandung, selected through purposive sampling. Data were collected through SmO₂ measurements using the Moxy Monitor during physical testing, along with physical condition measurements based on biomotor parameters. Data were analyzed using descriptive statistics, the Shapiro-Wilk normality test, Pearson correlation, simple linear regression, multiple linear regression, and path analysis. The results showed that the SmO₂ Ratio had a significant relationship with aerobic capacity (r = 0.766; p = 0.010) and physical condition (r = 0.727; p = 0.017), but no significant relationship with anaerobic capacity (r = 0.361; p = 0.305). Aerobic capacity had a very strong relationship with physical condition (r = 0.966; p = 0.000), while anaerobic capacity also showed a significant relationship (r = 0.810; p = 0.004). These findings indicate that an SmO₂-based energy system profile can be used as a physiological indicator for designing more precise physical conditioning programs based on the individual needs of badminton athletes. Keywords: Badminton, Moxy Monitor, Physical Conditioning, Energy System, SmO₂
Zitieren
APA
Khoir, I. F. M., Negara, J. D. K., & Gumilar, A. (2026). Profil Sistem Energi Berbasis Saturasi Oksigen Otot (SmO₂) Atlet Bulutangkis Menggunakan Moxy Monitor untuk Pengkondisian Fisik. Gelanggang Olahraga: Jurnal Pendidikan Jasmani dan Olahraga (JPJO), 9(5), 2206-2217. https://doi.org/10.31539/r1wdn815
Vancouver
Khoir IFM, Negara JDK, Gumilar A. Profil Sistem Energi Berbasis Saturasi Oksigen Otot (SmO₂) Atlet Bulutangkis Menggunakan Moxy Monitor untuk Pengkondisian Fisik. Gelanggang Olahraga: Jurnal Pendidikan Jasmani dan Olahraga (JPJO). 2026;9(5):2206-2217. doi:10.31539/r1wdn815
BibTeX
@article{Khoir2026,
author = {Khoir, Irman Felisiana Miftahul and Negara, Jajat Darajat Kusumah and Gumilar, Agus},
title = {Profil Sistem Energi Berbasis Saturasi Oksigen Otot (SmO₂) Atlet Bulutangkis Menggunakan Moxy Monitor untuk Pengkondisian Fisik},
journal = {Gelanggang Olahraga: Jurnal Pendidikan Jasmani dan Olahraga (JPJO)},
year = {2026},
volume = {9},
number = {5},
pages = {2206--2217},
doi = {10.31539/r1wdn815}
}
EUVIMED