Structural integrity of diesel generator set subjected to dynamic loads
International Journal for Engineering Modelling · 2020
DOI: 10.31534/engmod.2020.3-4.ri.01f ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal for Engineering Modelling, 2020.
Abstract (Originalsprache)
The integrity of the diesel generator set (genset) in the emergency power plant of a Nuclear Power Plant is considered. The genset consists of the diesel engine, the generator, and the common base frame on elastic spring-damper elements clamped to foundations. The genset is exposed to the seismic load, the short circuit impulse, and the synchronization failure load. The problem is solved via the finite element method (FEM). In the FE model, the diesel engine and the generator are represented with two lumped masses rigidly connected to the base frame with sets of massless bars. Strength criteria are specified according to the Russian Federal Codes and Standards in the Area of Atomic Energy Applications. The necessary number of spring-damper elements for preserving the integrity of the genset is determined.
Zitieren
APA
(2020). Structural integrity of diesel generator set subjected to dynamic loads. International Journal for Engineering Modelling. https://doi.org/10.31534/engmod.2020.3-4.ri.01f
Vancouver
Structural integrity of diesel generator set subjected to dynamic loads. International Journal for Engineering Modelling. 2020. doi:10.31534/engmod.2020.3-4.ri.01f
BibTeX
@article{euvimed2020,
title = {Structural integrity of diesel generator set subjected to dynamic loads},
journal = {International Journal for Engineering Modelling},
year = {2020},
doi = {10.31534/engmod.2020.3-4.ri.01f}
}