Integrated life cycle assessment of passive house envelope alternatives in a hot-arid climate: The case of the Gaziantep ecological house

Feride Çiğdem Kara Dülger, Merve Tuna Kayılı

Journal of Construction Engineering, Management & Innovation · 30.06.2026 · 9 (2) · 556-1-556-21

DOI: 10.31462/jcemi.2026.556 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Construction Engineering, Management & Innovation, online erschienen am 30.06.2026. Verfasst von Feride Çiğdem Kara Dülger und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The growing demand for energy-efficient buildings has led to the widespread adoption of Passive House (PH) standards, emphasizing operational energy reduction through optimized insulation and airtight construction. However, the embodied environmental impacts of building materials remain a critical concern. This study presents a Life Cycle Assessment of the Gaziantep Ecological House, Turkey’s first PH-certified building, focusing on both operational and embodied carbon emissions across its construction phases. The study evaluates the A1-A3 (material extraction, processing, and manufacturing) and A4 (transportation) stages, incorporating various wall construction scenarios to assess their environmental trade-offs. The results reveal that while high-performance insulation materials contribute to energy efficiency, their embodied carbon emissions can significantly impact sustainability. Among alternative wall materials, brick-based scenarios exhibited the highest global warming, acidification, and eutrophication potentials due to high-temperature kiln-firing and fossil fuel dependency. Conversely, adobe (earthen) walls demonstrated the lowest environmental impact across multiple categories, reinforcing their viability as a low-carbon construction material. However, challenges related to moisture resistance and structural performance require further investigation. Additionally, hempcrete, often perceived as an environmentally friendly material, showed higher-than-expected ozone depletion potential due to its cementitious binder content, highlighting the trade-offs between carbon sequestration benefits and secondary environmental burdens. The study also underscores the critical role of transportation emissions (A4 phase), where locally sourced materials such as adobe and autoclaved aerated concrete significantly reduced transport-related carbon emissions compared to imported alternatives. Overall, this research emphasizes the need for a balanced approach to sustainable construction, integrating both operational energy efficiency and embodied carbon reduction. Future studies should explore hybrid material strategies, bio-based insulation alternatives, and circular economy principles to further minimize lifecycle environmental impacts. By integrating LCA-driven decision-making into early-stage building design, policymakers, architects, and engineers can optimize passive house construction for long-term environmental sustainability.

Zitieren

APA

Dülger, F. Ç. K., & Kayılı, M. T. (2026). Integrated life cycle assessment of passive house envelope alternatives in a hot-arid climate: The case of the Gaziantep ecological house. Journal of Construction Engineering, Management & Innovation, 9(2), 556-1-556-21. https://doi.org/10.31462/jcemi.2026.556

Vancouver

Dülger FÇK, Kayılı MT. Integrated life cycle assessment of passive house envelope alternatives in a hot-arid climate: The case of the Gaziantep ecological house. Journal of Construction Engineering, Management & Innovation. 2026;9(2):556-1-556-21. doi:10.31462/jcemi.2026.556

BibTeX
@article{Dlger2026,
  author = {Dülger, Feride Çiğdem Kara and Kayılı, Merve Tuna},
  title = {Integrated life cycle assessment of passive house envelope alternatives in a hot-arid climate: The case of the Gaziantep ecological house},
  journal = {Journal of Construction Engineering, Management & Innovation},
  year = {2026},
  volume = {9},
  number = {2},
  pages = {556--1--556--21},
  doi = {10.31462/jcemi.2026.556}
}