Analyzing Illumination-Sensitive Failure – A Case Study
EDFA Technical Articles · 2000
DOI: 10.31399/asm.edfa.2000-1.p017 ↗Kurz gefasst
Fachartikel in der Zeitschrift EDFA Technical Articles, 2000. Verfasst von Teh Swee Thian.
Abstract (Originalsprache)
This is a case study of an illumination-sensitive failure. Due to the unavailability of a scanning optical microscope, fault isolation was performed using a different approach based on available equipment. Through a combination of emission microscopy, FIB isolation, mechanical probing, and in-depth circuit analysis, the root cause and failure mechanism were determined.
Zitieren
APA
Thian, T. S. (2000). Analyzing Illumination-Sensitive Failure – A Case Study. EDFA Technical Articles. https://doi.org/10.31399/asm.edfa.2000-1.p017
Vancouver
Thian TS. Analyzing Illumination-Sensitive Failure – A Case Study. EDFA Technical Articles. 2000. doi:10.31399/asm.edfa.2000-1.p017
BibTeX
@article{Thian2000,
author = {Thian, Teh Swee},
title = {Analyzing Illumination-Sensitive Failure – A Case Study},
journal = {EDFA Technical Articles},
year = {2000},
doi = {10.31399/asm.edfa.2000-1.p017}
}
EUVIMED