Fachartikel in der Zeitschrift Physiotherapy Canada, 2017-05. Verfasst von Melissa J Davidson und 3 weiteren Autor:innen. Beteiligte Einrichtung: Remarkable Physios Ltd., Queenstown, New Zealand. Die Arbeit wurde bisher 72-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The authors investigated the reliability of myotonometry-measured muscle tone in the thenar and perineal muscles.

Methods

Participants were women aged 18–50 years who were asymptomatic for thumb and pelvic floor dysfunction (interrater study n=20; intrarater study n=43) or who were symptomatic for vulvodynia (interrater study n=14; intrarater study n=32). Mechanical properties (stiffness, frequency, decrement, relaxation time, and creep) of the muscles were measured using a myotonometer (MyotonPRO) while the muscles were in a relaxed state. Measures were performed twice by two assessors. Intra- and interrater reliability were determined using intra-class correlation coefficients (ICCs) and absolute reliability using the standard error of measurement and a minimum detectable change.

Results

The primary property of interest, muscle stiffness, showed very good interrater (ICC 0.85–0.86) and intrarater (ICC 0.82–0.88) reliability in the thenar eminence. In the perineal muscles, reliability results ranged from good to very good for interrater (ICC 0.70–0.86) and intrarater (ICC 0.80–0.91) reliability for muscle stiffness. Absolute reliability was confirmed, with all measures showing minimal variance.

Conclusions

Muscle stiffness of the smaller muscles of the body can be reliably measured using the MyotonPRO. The device could be used as a reference standard in the development of a digital palpation scale that would facilitate accurate diagnosis of muscle tone.

Schlagwörter

Stichwörter der Autor:innen

muscleperineumreproducibility of resultsthumb

Autor:innen und Institutionen

  • Remarkable Physios Ltd., Queenstown, New Zealand.
  • Department of Physiotherapy, Faculty of Medicine, Dentistry, and Health Sciences, The University of Melbourne.
  • Sub-Acute Services, Royal Park Campus, The Royal Melbourne Hospital, Melbourne.
  • School of Allied Health, La Trobe University, Bundoora.
  • Centre for Allied Health Research and Education, Cabrini Health, Malvern, Vict., Australia.

Zitieren

APA

Davidson, M. J., Bryant, A. L., Bower, W. F., & Frawley, H. C. (2017). Myotonometry Reliably Measures Muscle Stiffness in the Thenar and Perineal Muscles. Physiotherapy Canada, 69(2), 104-112. https://doi.org/10.3138/ptc.2015-85

Vancouver

Davidson MJ, Bryant AL, Bower WF, Frawley HC. Myotonometry Reliably Measures Muscle Stiffness in the Thenar and Perineal Muscles. Physiotherapy Canada. 2017;69(2):104-112. doi:10.3138/ptc.2015-85

BibTeX
@article{Davidson2017,
  author = {Davidson, Melissa J and Bryant, Adam L and Bower, Wendy F and Frawley, Helena C},
  title = {Myotonometry Reliably Measures Muscle Stiffness in the Thenar and Perineal Muscles},
  journal = {Physiotherapy Canada},
  year = {2017},
  volume = {69},
  number = {2},
  pages = {104--112},
  doi = {10.3138/ptc.2015-85}
}
Kostenlos starten →