EUVIMEDEUVIMED entdecken
Systematische Übersicht

Quantifying Gaze Tracking for Visual Field Reliability Estimation. A Systematic Review

Luisa Fernanda Peña-Pulgar, Alejandro Tello, María Fernanda Acuña, Virgilio Galvis

Czech and Slovak Ophthalmology · 04.09.2025

DOI: 10.31348/2025/38 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Czech and Slovak Ophthalmology, online erschienen am 04.09.2025. Verfasst von Luisa Fernanda Peña-Pulgar und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Visual Field Tests, Visual Fields, Eye-Tracking Technology, Glaucoma.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

This systematic review aimed to investigate whether quantitative metrics derived from gaze tracking (GT) outputs during visual field (VF) testing with an automated perimeter could enhance the evaluation of test reliability. Materials and Methods: A systematic search of PubMed, Cochrane, LILACS, and IBECS databases, from inception to August 31, 2024, was conducted.

Results

Eight studies – four cross-sectional and four cohort – met the inclusion criteria, comprising 8,181 visual field tests from 3,687 patients. The studies were categorized based on testing strategy: SITA Standard, Fast, and Faster. In the SITA Standard group, GT parameters were associated with visual field result reproducibility and the structure-function relationship in glaucoma, but were influenced by ocular surface variables. In the SITA Fast and Faster group, results were mixed: some studies suggested GT metrics could complement conventional reliability parameters, while others concluded that GT quantitative metrics did not offer clinically meaningful insights beyond existing methods.

Conclusion

GT trace quantification shows promise as an objective reliability parameter for VF testing, particularly within the SITA Standard framework. Advanced image analysis techniques, including artificial intelligence, could facilitate automated GT parameter quantification, streamlining processes and supporting further studies to evaluate their impact on VF data reliability and clinical decision-making.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual Field TestsVisual FieldsEye-Tracking TechnologyGlaucomaHumansReproducibility of Results

Stichwörter der Autor:innen

automated perimetrygaze trackingglaucomavisual field

Zitieren

APA

Peña-Pulgar, L. F., Tello, A., Acuña, M. F., & Galvis, V. (2025). Quantifying Gaze Tracking for Visual Field Reliability Estimation. A Systematic Review. Czech and Slovak Ophthalmology. https://doi.org/10.31348/2025/38

Vancouver

Peña-Pulgar LF, Tello A, Acuña MF, Galvis V. Quantifying Gaze Tracking for Visual Field Reliability Estimation. A Systematic Review. Czech and Slovak Ophthalmology. 2025. doi:10.31348/2025/38

BibTeX
@article{PeaPulgar2025,
  author = {Peña-Pulgar, Luisa Fernanda and Tello, Alejandro and Acuña, María Fernanda and Galvis, Virgilio},
  title = {Quantifying Gaze Tracking for Visual Field Reliability Estimation. A Systematic Review},
  journal = {Czech and Slovak Ophthalmology},
  year = {2025},
  doi = {10.31348/2025/38}
}
Kostenlos starten →