Internal jugular vein distensibility: Rapid and reliable bedside assessment tool to predict fluid responsiveness in mechanically ventilated septic patients

Shubha K. Shrestha, Gentle S. Shrestha, Hem R. Paneru, Pramesh S. Shrestha, Bishwas Pradhan, Subhash P. Acharya

Journal of Advances in Internal Medicine · 2022

DOI: 10.3126/jaim.v11i1.48192 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Advances in Internal Medicine, 2022. Verfasst von Shubha K. Shrestha und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aims: This study aims to evaluate whether respiratory changes in internal jugular vein (IJV) diameter predicts fluid responsiveness in mechanically ventilated patients with sepsis.

Methods

In this prospective observational analytic study, mechanically ventilated patients in septic shock received 7ml/kg of Normal Saline (NS) over 15 minutes. Patients were then categorized into two groups retrospectively; fluid responders (R), if there was an increment in Cardiac Index (CI) by more than or equal to 15% following fluid administration, and non-responders (NR) if the increase in CI was less than 15%. The primary outcome was respiratory changes in IJV diameter before and after fluid administration. Ultrasonographic assessment of IJV distensibility was carried out in all mechanically ventilated septic patients before and after fluid administration.

Results

In our study, 74 mechanically ventilated septic patients were enrolled. Among them, 29 (39.2%) patients were fluid responders whereas 45 (60.8%) patients were non-responders. Responders demonstrated higher IJV distensibility before volume expansion than non-responders (33.33% vs 16.9%; P 28.2% before fluid administration predicted the change in CI ≥15% with 90% sensitivity and 100% specificity with area under curve of 0.985 (CI 0.963 to 1.006).

Conclusion

Ultrasound evaluation of respiratory changes in IJV distensibility effectively predicts fluid responsiveness in mechanically ventilated septic patients.

Zitieren

APA

Shrestha, S. K., Shrestha, G. S., Paneru, H. R., Shrestha, P. S., Pradhan, B., & Acharya, S. P. (2022). Internal jugular vein distensibility: Rapid and reliable bedside assessment tool to predict fluid responsiveness in mechanically ventilated septic patients. Journal of Advances in Internal Medicine. https://doi.org/10.3126/jaim.v11i1.48192

Vancouver

Shrestha SK, Shrestha GS, Paneru HR, Shrestha PS, Pradhan B, Acharya SP. Internal jugular vein distensibility: Rapid and reliable bedside assessment tool to predict fluid responsiveness in mechanically ventilated septic patients. Journal of Advances in Internal Medicine. 2022. doi:10.3126/jaim.v11i1.48192

BibTeX
@article{Shrestha2022,
  author = {Shrestha, Shubha K. and Shrestha, Gentle S. and Paneru, Hem R. and Shrestha, Pramesh S. and Pradhan, Bishwas and Acharya, Subhash P.},
  title = {Internal jugular vein distensibility: Rapid and reliable bedside assessment tool to predict fluid responsiveness in mechanically ventilated septic patients},
  journal = {Journal of Advances in Internal Medicine},
  year = {2022},
  doi = {10.3126/jaim.v11i1.48192}
}
Kostenlos starten →