3D Frequency-Difference Electrical Impedance Tomography for Early Subcutaneous Edema Detection Using Tikhonov Regularization and Physics-Informed Neural Networks

Anish Maharjan, Sanjeeb Prasad Panday, Lok Nath Regmi

International Journal on Engineering Technology · 18.06.2026 · 3 (2) · 52-61

DOI: 10.3126/injet.v3i2.95499 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal on Engineering Technology, online erschienen am 18.06.2026. Verfasst von Anish Maharjan und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Subcutaneous edema is difficult to detect at an early stage because the associated conductivity changes are subtle and hard to localize using conventional imaging methods. This study presents the 3D Frequency Difference-Electrical Impedance Tomography (FD-EIT) framework for the detection of early-stage edema in the lower leg region. A 3D lower-leg model with 16 electrodes was simulated, and the boundary voltages and differential measurements were generated under a broader set of synthetic edema scenarios representing varied anomaly extent, irregularity, conductivity, contrast, and measurement difficulty. Reconstruction was evaluated using two approaches: the baseline method using Tikhonov regularization and the Physics-Informed Neural Network (PINN) method. The results show that the baseline method produces stable but spatially diffuse reconstructions, whereas the PINN method provides more localized and structured anomaly patterns that are aligned more closely with the ground-truth edema regions. Quantitative evaluation with RMSE, MAE, relative error, and Dice score showed better reconstruction accuracy and edema-mask localization for the PINN compared to the baseline method. However, the results should be interpreted as a controlled synthetic proof-of-concept because the PINN was trained and evaluated using scenario-specific simulated data. Therefore, the reported localization performance does not represent clinical diagnostic accuracy. Future work will focus on realistic anatomical modeling, electrode contact effects, phantom validation, and experimental lower-leg measurements.

Zitieren

APA

Maharjan, A., Panday, S. P., & Regmi, L. N. (2026). 3D Frequency-Difference Electrical Impedance Tomography for Early Subcutaneous Edema Detection Using Tikhonov Regularization and Physics-Informed Neural Networks. International Journal on Engineering Technology, 3(2), 52-61. https://doi.org/10.3126/injet.v3i2.95499

Vancouver

Maharjan A, Panday SP, Regmi LN. 3D Frequency-Difference Electrical Impedance Tomography for Early Subcutaneous Edema Detection Using Tikhonov Regularization and Physics-Informed Neural Networks. International Journal on Engineering Technology. 2026;3(2):52-61. doi:10.3126/injet.v3i2.95499

BibTeX
@article{Maharjan2026,
  author = {Maharjan, Anish and Panday, Sanjeeb Prasad and Regmi, Lok Nath},
  title = {3D Frequency-Difference Electrical Impedance Tomography for Early Subcutaneous Edema Detection Using Tikhonov Regularization and Physics-Informed Neural Networks},
  journal = {International Journal on Engineering Technology},
  year = {2026},
  volume = {3},
  number = {2},
  pages = {52--61},
  doi = {10.3126/injet.v3i2.95499}
}