EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Physiological and environmental assessment of heat strain risk among welders using the predicted heat strain model

Moch. Sahri, Farahul Jannah, Friska Ayu, Muslikha Nourma Rhomadhoni, Abdul Hakim Zakkiy Fasya

International Journal of Occupational Safety and Health · 10.07.2026 · 16 (2) · 367-377

DOI: 10.3126/ijosh.v16i2.79825 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Occupational Safety and Health, online erschienen am 10.07.2026. Verfasst von Moch. Sahri und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Welders are routinely exposed to high thermal loads, increasing the risk of heat stress. Environmental indices such as the Wet-Bulb Globe Temperature (WBGT) are commonly used for assessment but do not account for individual physiological responses. This study aimed to evaluate heat strain among welders using the Predicted Heat Strain (PHS) model defined by ISO 7933:2018, which integrates environmental and physiological factors.

Methods

An observational study was conducted involving 41 male welders. Environmental parameters—including dry-bulb, wet-bulb, globe temperature, relative humidity, and air velocity—were measured three times during an 8-hour shift using a QUEST Temp° 44 monitor. Metabolic rate was estimated through task observation and standardized values. Predicted water loss was calculated using the PHS model through the FAME Lab PHS Calculator. Statistical analysis, including an independent samples t-test, was performed using Python in Google Colaboratory.

Results

All participants experienced predicted water loss exceeding the 5% threshold recommended by ISO 7933:2018, ranging from 6.02% to 14.59%. The average WBGT was 26.11 °C, above the 25 °C limit for very high metabolic workloads. Participants with body weight below 65 kg had significantly higher proportional water loss (mean = 12.29%, SD = 1.62) compared to those with ≥65 kg (mean = 9.11%, SD = 1.51; t = 6.50, p < 0.001).

Conclusion

Welders face substantial heat strain risk, particularly those with lower body mass. Combining physiological modeling with environmental assessment offers a more complete evaluation of heat exposure risks. Preventive strategies should address both environmental and individual factors to enhance worker protection.

Zitieren

APA

Sahri, M., Jannah, F., Ayu, F., Rhomadhoni, M. N., & Fasya, A. H. Z. (2026). Physiological and environmental assessment of heat strain risk among welders using the predicted heat strain model. International Journal of Occupational Safety and Health, 16(2), 367-377. https://doi.org/10.3126/ijosh.v16i2.79825

Vancouver

Sahri M, Jannah F, Ayu F, Rhomadhoni MN, Fasya AHZ. Physiological and environmental assessment of heat strain risk among welders using the predicted heat strain model. International Journal of Occupational Safety and Health. 2026;16(2):367-377. doi:10.3126/ijosh.v16i2.79825

BibTeX
@article{Sahri2026,
  author = {Sahri, Moch. and Jannah, Farahul and Ayu, Friska and Rhomadhoni, Muslikha Nourma and Fasya, Abdul Hakim Zakkiy},
  title = {Physiological and environmental assessment of heat strain risk among welders using the predicted heat strain model},
  journal = {International Journal of Occupational Safety and Health},
  year = {2026},
  volume = {16},
  number = {2},
  pages = {367--377},
  doi = {10.3126/ijosh.v16i2.79825}
}
Kostenlos starten →