Comparison of the Results of Automatic Blood Analyser and Manual Peripheral Smear Method in Total and Differential Leukocyte Count in Goats

Gülten Emek Tuna

Harran Üniversitesi Veteriner Fakültesi Dergisi · 2022

DOI: 10.31196/huvfd.1096972 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Harran Üniversitesi Veteriner Fakültesi Dergisi, 2022. Verfasst von Gülten Emek Tuna. Die Arbeit nennt 23 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Abacus Vet 5 (AV5) is a volumetric impedance-based automated haematology analyser that offers a total and 3-part differential (lymphocytes, neutrophils and monocytes) white blood cell (WBC) count in goats. This study aimed to compare the total and differential leukocyte counts (absolute and relative) measured with the AV5 haematology analyser with the results obtained by the manual method from blood smears in goats. It is also aimed to compare the compatibility between the two methods. The blood samples of 40 hair goats (9 healthy and 31 diseased) were analysed by both methods. The relationships between the values were evaluated with a correlation coefficient, and the agreements between the methods were assessed with the Bland-Altman method. The correlation between two methods were excellent for total WBC counts (rho = 0.963, p = 0.000), absolute neutrophils (rho = 0.964, p = 0.000), lymphocytes (rho = 0.928, p = 0.000), a good for the neutrophil percentages (rho = 0.824, p = 0.000), and a weak for absolute monocytes (rho = 0.426, p = 0.006). Although the bias for lymphocyte (−8.25 %) and neutrophil (10.02 %) percentages was relatively significant and the confidence intervals were wide, the agreement for all parameters was acceptable between the two methods in the Bland atman method. In conclusion, the AV5 haematology analyser performed well for total, and differential WBCs counts in goats. However, abnormal results should still be confirmed by a blood smear examination. In addition, instrument performance evaluations, including increased sample sizes, should be performed in further studies.

Zitieren

APA

Tuna, G. E. (2022). Comparison of the Results of Automatic Blood Analyser and Manual Peripheral Smear Method in Total and Differential Leukocyte Count in Goats. Harran Üniversitesi Veteriner Fakültesi Dergisi. https://doi.org/10.31196/huvfd.1096972

Vancouver

Tuna GE. Comparison of the Results of Automatic Blood Analyser and Manual Peripheral Smear Method in Total and Differential Leukocyte Count in Goats. Harran Üniversitesi Veteriner Fakültesi Dergisi. 2022. doi:10.31196/huvfd.1096972

BibTeX
@article{Tuna2022,
  author = {Tuna, Gülten Emek},
  title = {Comparison of the Results of Automatic Blood Analyser and Manual Peripheral Smear Method in Total and Differential Leukocyte Count in Goats},
  journal = {Harran Üniversitesi Veteriner Fakültesi Dergisi},
  year = {2022},
  doi = {10.31196/huvfd.1096972}
}
Kostenlos starten →