Reliability and Functional Associations of VentriJect Seismofit® VO2 Estimates
Journal of Clinical Exercise Physiology · 22.07.2026
DOI: 10.31189/ceph-25-00038 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Exercise Physiology, erschienen am 22.07.2026. Verfasst von Luke Del Vecchio und 1 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben.
Abstract (Originalsprache)
Introduction
Cardiorespiratory fitness is a key determinant of morbidity, mortality, and functional independence in older adults. Direct measurement of maximal oxygen consumption (VO 2 max) through cardiopulmonary exercise testing (CPET) is resource intensive and often inacc in community-based exercise physiology practice. Emerging nonexercise technologies such as the VentriJect Seismofit® (VS) offer a practical alternative, yet evidence of its accuracy and reliability in older adults and walking modalities is limited.
Methods
Thirty community-dwelling adults (53–69 years) completed the Adult Pre-Exercise Screening System questionnaire and underwent a submaximal graded treadmill test (Bruce protocol; terminated at 85% age-predicted maximal heart rate or rating of perceived exertion of 15). VO 2 max was estimated using the VS device in duplicate for reliability. Predicted VO 2 max was compared against treadmill-derived metabolic equivalents (METs) using Pearson correlation and linear regression.
Results
VS-estimated VO 2 max was significantly correlated with Bruce treadmill performance ( r = 0.45, P = .012), explaining 20% of the variance. The regression slope indicated a 0.21 MET increase per 1 mL·kg −1 ·min −1 VO 2 max. Participants were distributed across stages 2–4 METs, linking to activities of daily living from brisk walking to jogging. Test-retest reliability of VS estimates was excellent ( r = 0.98).
Conclusions
VS-derived VO 2 max estimates show promise as a practical tool for predicting functional capacity in middle-aged and older adults. With further validation, non-exercise assessment may enable exercise physiologists to streamline functional evaluation and tailor activity counselling in settings with limited access to CPET.
Zitieren
APA
Vecchio, L. D., & Climstein, M. (2026). Reliability and Functional Associations of VentriJect Seismofit® VO2 Estimates. Journal of Clinical Exercise Physiology. https://doi.org/10.31189/ceph-25-00038
Vancouver
Vecchio LD, Climstein M. Reliability and Functional Associations of VentriJect Seismofit® VO2 Estimates. Journal of Clinical Exercise Physiology. 2026. doi:10.31189/ceph-25-00038
BibTeX
@article{Vecchio2026,
author = {Vecchio, Luke Del and Climstein, Mike},
title = {Reliability and Functional Associations of VentriJect Seismofit® VO2 Estimates},
journal = {Journal of Clinical Exercise Physiology},
year = {2026},
doi = {10.31189/ceph-25-00038}
}
EUVIMED