Banding of a Ptfe Hemodialysis Fistula in the Treatment of Steal Syndrome
Clinical and Experimental Dialysis and Apheresis · 1981
DOI: 10.3109/08860228109076017 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical and Experimental Dialysis and Apheresis, 1981. Verfasst von A Ebeid und 1 weiteren Autor:innen. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 5 Literaturangaben.
Abstract (Originalsprache)
The construction of various types of access fistulas for hemodialysis has been known to be followed by ischemic symptoms distal to the anastomosis. The occurrence of a steal phenomenon as a complication of a PTFE (Gortex) fistula is often serious enough to necessitate taking down the fistula. A typical patient with this steal phenomenon is presented illustrating the value of banding the graft to reverse steal without significant threat of thrombosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Zitieren
APA
Ebeid, A., & Saranchak, H. J. (1981). Banding of a Ptfe Hemodialysis Fistula in the Treatment of Steal Syndrome. Clinical and Experimental Dialysis and Apheresis. https://doi.org/10.3109/08860228109076017
Vancouver
Ebeid A, Saranchak HJ. Banding of a Ptfe Hemodialysis Fistula in the Treatment of Steal Syndrome. Clinical and Experimental Dialysis and Apheresis. 1981. doi:10.3109/08860228109076017