EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparative Efficacy of Integrated Stent-Graft versus Conventional Covered Stent-Graft Alone in Type B Aortic Dissection: A Retrospective Study Focusing on Aortic Remodeling and Branch Perfusion

Jieyu Cao iD, Zhengwen Lei iD, Keke Xu, Shuangxi He iD, Jun Hu, Linfei Xing, Juan Luo

Reviews in Cardiovascular Medicine · 24.06.2026 · 27 (6)

DOI: 10.31083/rcm49740 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Reviews in Cardiovascular Medicine, online erschienen am 24.06.2026. Verfasst von Jieyu Cao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, The First Affiliated Hospital, Hengyang Medical School, University of South China, 421001 Hengyang, Hunan, Chin…. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background:To compare the early efficacy of an integrated stent-graft (16-cm covered stent combined with a 6-cm distal bare stent) versus a conventional covered stent-graft alone in patients with acute type B aortic dissection (TBAD), with a focus on aortic remodeling and branch artery perfusion.Methods:In this single-center retrospective cohort study, 102 patients were included (integrated stent-graft: n = 34; conventional stent-graft: n = 68). Aortic remodeling was assessed using the true lumen area ratio at five predefined anatomical planes. Branch artery perfusion patterns and procedure-related complications were evaluated preoperatively and at 3-month follow-up.Results:At 3 months, the integrated stent-graft group demonstrated significantly higher true lumen area ratios at the left subclavian artery plane 0.60 (0.41, 0.63) vs. 0.41 (0.25, 0.54), p = 0.002; pulmonary artery plane 0.65 (0.54, 0.71) vs. 0.44 (0.38, 0.53), p < 0.001; and diaphragmatic plane 0.61 (0.50, 0.76) vs. 0.44 (0.37, 0.51), p < 0.001. No significant differences were observed at the renal or iliac planes. Regarding branch perfusion, a significant overall difference in postoperative perfusion pattern distribution was observed for the celiac trunk (p = 0.027) and left renal artery (p = 0.017). No differences were detected in other branch arteries. The incidence of postoperative new entry tears was lower in the integrated stent-graft group (23.5% vs. 41.2%), although this difference did not reach statistical significance (p = 0.079).Conclusions:In this exploratory retrospective study with short-term (3-month) follow-up, the integrated stent-graft system was associated with improved early true lumen remodeling in the proximal and mid-aortic segments and differences in branch artery perfusion patterns compared with a conventional covered stent-graft alone. A trend toward fewer new entry tears was observed, but given the limited follow-up and sample size, these findings should be considered preliminary. Confirmation in larger prospective studies with long-term follow-up is warranted to determine whether these early imaging changes translate into durable clinical benefit.

Schlagwörter

Stichwörter der Autor:innen

aortic remodelingbare-metal stentbranch arteryintegrated stent-graft systemthoracic endovascular aortic repairtype B aortic dissection

Autor:innen und Institutionen

  • Department of Cardiothoracic Surgery, The First Affiliated Hospital, Hengyang Medical School, University of South China, 421001 Hengyang, Hunan, China.
  • School of Nursing, University of South China, 421001 Hengyang, Hunan, China.
  • Department of Cardiothoracic Surgery, The Second Affiliated Hospital, Hengyang Medical School, University of South China, 421001 Hengyang, Hunan, China.
  • Hengyang Medical School, University of South China, 421001 Hengyang, Hunan, China.

ORCID-Profile: Jieyu Cao, Zhengwen Lei, Shuangxi He

Zitieren

APA

Cao, J., Lei, Z., Xu, K., He, S., Hu, J., Xing, L., & Luo, J. (2026). Comparative Efficacy of Integrated Stent-Graft versus Conventional Covered Stent-Graft Alone in Type B Aortic Dissection: A Retrospective Study Focusing on Aortic Remodeling and Branch Perfusion. Reviews in Cardiovascular Medicine, 27(6). https://doi.org/10.31083/rcm49740

Vancouver

Cao J, Lei Z, Xu K, He S, Hu J, Xing L, et al. Comparative Efficacy of Integrated Stent-Graft versus Conventional Covered Stent-Graft Alone in Type B Aortic Dissection: A Retrospective Study Focusing on Aortic Remodeling and Branch Perfusion. Reviews in Cardiovascular Medicine. 2026;27(6). doi:10.31083/rcm49740

BibTeX
@article{Cao2026,
  author = {Cao, Jieyu and Lei, Zhengwen and Xu, Keke and He, Shuangxi and Hu, Jun and Xing, Linfei and Luo, Juan},
  title = {Comparative Efficacy of Integrated Stent-Graft versus Conventional Covered Stent-Graft Alone in Type B Aortic Dissection: A Retrospective Study Focusing on Aortic Remodeling and Branch Perfusion},
  journal = {Reviews in Cardiovascular Medicine},
  year = {2026},
  volume = {27},
  number = {6},
  doi = {10.31083/rcm49740}
}
Kostenlos starten →