EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effectiveness of the Clinical Decision Support System Upgrade in the Automated Unit Dose Drug Dispensing System

Kui Zhao, Jianglin Li, Mianwei Chen, Xian Zou, Lin Cheng

Die Pharmazie · 17.06.2026 · 81 (6)

DOI: 10.31083/pharmazie51382 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Die Pharmazie, online erschienen am 17.06.2026. Verfasst von Kui Zhao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern Un…. Hauptthemen laut MEDLINE: Decision Support Systems, Clinical, Medication Systems, Hospital. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research project on high-quality development of Hospital pharmacy, National Institute of Hospital Administration, NHC.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective:This study aims to evaluate the effectiveness of the clinical decision support system (CDSS) upgrade in the automated unit-dose drug dispensing system (AUDDS), which comprises both the pre-review CDSS software of the automated drug unit-dose dispensing machine (ADDM) and the pre-verify CDSS software of the medication detection machine (MDM). The ultimate goal of these coordinated enhancements is to improve the overall dispensing efficiency of the AUDDS.Methods:A multidisciplinary collaboration involving pharmacists and the AUDDS engineer was established to implement two upgrades: the rule-based pre-review CDSS software in ADDM and the pre-verify CDSS software in MDM. The upgraded CDSS software of ADDM was configured to automatically identify and intercept three categories of clinically inappropriate inpatient medication orders (IMOs) based on real-time patient data from the hospital information system: duplicate IMOs, IMOs of excessive doses, and non-splittable IMOs. Upon detection, the CDSS software in ADDM generates an alert to notify the managing pharmacist, who conducts a telephone consultation with the prescribing doctor for timely resolution. The pre-verify CDSS software in MDM was upgraded to improve image acquisition and recognition accuracy and reduce the error rate in automatically identifying mismatched unit-dose medication bags (UMBs).Results:Pre-post comparisons revealed improvements in both workload and efficiency metrics and safety metrics. After the upgrade, total order volume (TOV) and order volume per pharmacist (OVP) showed a 7.54% mean increase, and the monthly total number of pre-verified unit-dose medication bags (MTN) revealed a 31.84% mean increase. The monthly volume of duplicate IMOs (MVDI) displayed a 11.62% mean reduction, and the ratio of duplicate IMOs (RDI) displayed a 19.32% mean reduction. The monthly volume of IMOs with excessive doses (MVIE) revealed a 35.20% mean reduction, and the ratio of IMOs with excessive doses (RIE) displayed a 41.78% mean reduction. The monthly true-positive error rate (MTER) displayed a 16.29% mean reduction. However, the monthly false-positive error rate (MFER) was higher after the upgrade. Non-splittable IMOs were rare in the study, so they were excluded from the comparison.Conclusion:This study demonstrates that the upgrade was associated with improvement of the appropriateness of long-term IMOs and the dispensing efficiency of AUDDS, thereby enhancing medication safety in hospital pharmacies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Decision Support Systems, ClinicalMedication Systems, HospitalHumansSoftwareMedication ErrorsPharmacistsAutomationPharmacy Service, HospitalMedical Order Entry Systems

Stichwörter der Autor:innen

decision support systems, clinicalmedication errorsmedication systemspharmaceutical services

Autor:innen und Institutionen

  • Department of Pharmacy, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), 518020 Shenzhen, Guangdong, China.

Förderung

  • Research project on high-quality development of Hospital pharmacy, National Institute of Hospital Administration, NHC

Zitieren

APA

Zhao, K., Li, J., Chen, M., Zou, X., & Cheng, L. (2026). Effectiveness of the Clinical Decision Support System Upgrade in the Automated Unit Dose Drug Dispensing System. Die Pharmazie, 81(6). https://doi.org/10.31083/pharmazie51382

Vancouver

Zhao K, Li J, Chen M, Zou X, Cheng L. Effectiveness of the Clinical Decision Support System Upgrade in the Automated Unit Dose Drug Dispensing System. Die Pharmazie. 2026;81(6). doi:10.31083/pharmazie51382

BibTeX
@article{Zhao2026,
  author = {Zhao, Kui and Li, Jianglin and Chen, Mianwei and Zou, Xian and Cheng, Lin},
  title = {Effectiveness of the Clinical Decision Support System Upgrade in the Automated Unit Dose Drug Dispensing System},
  journal = {Die Pharmazie},
  year = {2026},
  volume = {81},
  number = {6},
  doi = {10.31083/pharmazie51382}
}
Kostenlos starten →