A Novel Long-Term Intrathecal Cannulation Technique in Rats: L5-L6 Approach With Cervical Externalization for Chronic Drug Delivery
Journal of Integrative Neuroscience · 21.11.2025 · 24 (11)
DOI: 10.31083/jin45111 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Integrative Neuroscience, online erschienen am 21.11.2025. Verfasst von Wen-Ming Zhou und 8 weiteren Autor:innen. Beteiligte Einrichtung: The Second Hospital & Clinical Medical School, Lanzhou University, 730000 Lanzhou, Gansu, China. Hauptthemen laut MEDLINE: Injections, Spinal, Catheterization, Drug Delivery Systems, Spinal Cord. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Lanzhou University Second Hospital Cuiying Youth Fund Project, Cuiying Science and Technology Innovation Program Project.
Abstract (Originalsprache)
Background and Purpose: Current intrathecal (IT) catheter techniques in rats are problematic due to complex surgical procedures and frequent blockages. This study developed a simpler, faster, and more reliable method for long-term IT catheter placement.
Methods
Fifty adult male Sprague-Dawley rats were randomly divided into three groups: IT group (n = 30), Sham group (n = 10), and Control group (n = 10). We inserted a polytetrafluoroethylene (PTFE) catheter (0.5-mm outer diameter, 0.3-mm inner diameter) into the cauda equina, reaching a depth of 0.5–1 cm via the L5–L6 intervertebral space. Then catheter was tunneled subcutaneously, exiting at the dorsal neck, and held in place with mechanical compression. We assessed safety and efficacy over 12 weeks through behavioral testing, functional evaluations, and immunofluorescence analysis.
Results
Surgery took an average of 7.2 ± 1.8 min, with a 93.3% first-attempt success rate. Remarkably, all catheters remained patent throughout the 12-week study period (100% patency). Behavioral tests showed no changes in pain sensitivity, although rats did experience a temporary reduction in weight gain during the first postoperative week (p < 0.01). Lidocaine testing confirmed proper catheter function, with motor block occurring rapidly (onset: 30 ± 5 s), followed by complete recovery. Lipopolysaccharide doses of 3, 15, and 30 μg demonstrated clear dose-dependent inflammatory responses, confirming accurate drug delivery. Western blot analysis confirmed no chronic inflammation, with interleukin 1 beta (IL-1β), IL-6, and tumor necrosis factor alpha expression in the IT-Saline group comparable with controls (p > 0.05). Immunofluorescence analysis revealed no significant activation of microglia (ionized calcium-binding adaptor molecule 1) or astrocytes (glial fibrillary acidic protein) based on mean fluorescence intensity, with preserved neuronal density (NeuN-positive cells) comparable with controls.
Conclusion
Our L5–L6 approach effectively minimized the risk of spinal cord injury. The choice of PTFE material proved crucial, as it enabled 100% long-term patency, a result not achieved with other materials. Combined with the neck-mounted external design, this technique offers an improved approach for repeated IT drug delivery in rat models, but more studies are needed to confirm its effectiveness in a wider range of pharmacological applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Second Hospital & Clinical Medical School, Lanzhou University, 730000 Lanzhou, Gansu, China.
- Orthopaedics Key Laboratory of Gansu Province, 730000 Lanzhou, Gansu, China.
Förderung
- National Natural Science Foundation of China
- Lanzhou University Second Hospital Cuiying Youth Fund Project
- Cuiying Science and Technology Innovation Program Project
- Lanzhou Youth Science and technology Talents Innovation Project
- Natural Science Foundation of Gansu Province
Zitieren
APA
Zhou, W. M., Zhang, K., Shi, Y. Q., Ran, R., Dong, Y. B., Zhao, G. H., Ma, Y. C., Nan, W., & Zhang, H. H. (2025). A Novel Long-Term Intrathecal Cannulation Technique in Rats: L5-L6 Approach With Cervical Externalization for Chronic Drug Delivery. Journal of Integrative Neuroscience, 24(11). https://doi.org/10.31083/jin45111
Vancouver
Zhou WM, Zhang K, Shi YQ, Ran R, Dong YB, Zhao GH, et al. A Novel Long-Term Intrathecal Cannulation Technique in Rats: L5-L6 Approach With Cervical Externalization for Chronic Drug Delivery. Journal of Integrative Neuroscience. 2025;24(11). doi:10.31083/jin45111
BibTeX
@article{Zhou2025,
author = {Zhou, Wen-Ming and Zhang, Kai and Shi, Yong-Qiang and Ran, Rui and Dong, Yan-Bo and Zhao, Guang-Hai and Ma, Yan-Chao and Nan, Wei and Zhang, Hai-Hong},
title = {A Novel Long-Term Intrathecal Cannulation Technique in Rats: L5-L6 Approach With Cervical Externalization for Chronic Drug Delivery},
journal = {Journal of Integrative Neuroscience},
year = {2025},
volume = {24},
number = {11},
doi = {10.31083/jin45111}
}
EUVIMED