Kurz gefasst

Fachartikel in der Zeitschrift Journal of Integrative Neuroscience, online erschienen am 19.08.2024. Verfasst von Eleanor Duckworth und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Neurophysiology, Great Ormond Street Hospital for Children, WC1N 3JH London, UK. Hauptthemen laut MEDLINE: Electroencephalography, Seizures. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Neonatal seizures are diagnostically challenging and predominantly electrographic-only. Multichannel video continuous electroencephalography (cEEG) is the gold standard investigation, however, out-of-hours access to neurophysiology support can be limited. Automated seizure detection algorithms (SDAs) are designed to detect changes in EEG data, translated into user-friendly seizure probability trends. The aim of this study was to evaluate the diagnostic accuracy of the Persyst neonatal SDA in an intensive care setting.

Methods

Single-centre retrospective service evaluation study in neonates undergoing cEEG during intensive care admission to Great Ormond Street Hospital (GOSH) between May 2019 and December 2022. Neonates with 60 minutes, whilst inpatient in intensive care, were included in the study. One-hour cEEG clips were created for all cases (seizures detected) and controls (seizure-free) and analysed by the Persyst neonatal SDA. Expert neurophysiology reports of the cEEG recordings were used as the gold standard for diagnostic comparison. A receiver operating characteristic (ROC) curve was created using the highest seizure probability in each recording. Optimal seizure probability thresholds for sensitivity and specificity were identified.

Results

Eligibility screening produced 49 cases, and 49 seizure-free controls. Seizure prevalence within those patients eligible for the study, was approximately 19% with 35% mortality. The most common case seizure aetiology was hypoxic ischaemic injury (35%) followed by inborn errors of metabolism (18%). The ROC area under the curve was 0.94 with optimal probability thresholds 0.4 and 0.6. Applying a threshold of 0.6, produced 80% sensitivity and 98% specificity.

Conclusions

The Persyst neonatal SDA demonstrates high diagnostic accuracy in identifying neonatal seizures; comparable to the accuracy of the standard Persyst SDA in adult populations, other neonatal SDAs, and amplitude integrated EEG (aEEG). Overdiagnosis of seizures is a risk, particularly from cEEG recording artefact. To fully examine its clinical utility, further investigation of the Persyst neonatal SDA’s accuracy is required, as well as confirming the optimal seizure probability thresholds in a larger patient cohort.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectroencephalographySeizuresHumansInfant, NewbornRetrospective StudiesFemaleMaleSensitivity and SpecificityAlgorithmsVideo Recording

Stichwörter der Autor:innen

EEGautomated detectionelectroencephalogramintensive careneonateseizurestatus epilepticus

Autor:innen und Institutionen

  • Department of Clinical Neurophysiology, Great Ormond Street Hospital for Children, WC1N 3JH London, UK.
  • Neonatal Intensive Care Unit, Great Ormond Street Hospital for Children, WC1N 3JH London, UK.
  • Clinical Neuroscience, University College London, UCL, Great Ormond Street Institute of Child Health, WC1N 1EH London, UK.

Zitieren

APA

Duckworth, E., Motan, D., Howse, K., Boyd, S., Pressler, R., & Chalia, M. (2024). Diagnostic Accuracy of the Persyst Automated Seizure Detector in the Neonatal Population. Journal of Integrative Neuroscience, 23(8). https://doi.org/10.31083/j.jin2308150

Vancouver

Duckworth E, Motan D, Howse K, Boyd S, Pressler R, Chalia M. Diagnostic Accuracy of the Persyst Automated Seizure Detector in the Neonatal Population. Journal of Integrative Neuroscience. 2024;23(8). doi:10.31083/j.jin2308150

BibTeX
@article{Duckworth2024,
  author = {Duckworth, Eleanor and Motan, Daniyal and Howse, Kitty and Boyd, Stewart and Pressler, Ronit and Chalia, Maria},
  title = {Diagnostic Accuracy of the Persyst Automated Seizure Detector in the Neonatal Population},
  journal = {Journal of Integrative Neuroscience},
  year = {2024},
  volume = {23},
  number = {8},
  doi = {10.31083/j.jin2308150}
}
Kostenlos starten →