A Highly Selective and Sensitive Fluorescent Probe With a Large Stokes Shift for Near-Infrared Visualization of Endogenous and Exogenous Biothiols in Living Cells
Frontiers in Bioscience-Landmark · 2025
DOI: 10.31083/fbl37240 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Bioscience-Landmark, 2025. Verfasst von Xiaomin Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Shaanxi Key Laboratory of Chemical Additives for Industry, College of Chemistry and Chemical Engineering, Shaanxi University of Science & Technology,…. Hauptthemen laut MEDLINE: Fluorescent Dyes, Sulfhydryl Compounds. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Plan Project of Xi'an, Science and Technology Plan Project of Weiyang District, Science and Technology Plan Project of Xi’an.
Abstract (Originalsprache)
Background
Fluorescent probes have become a powerful tool for monitoring biothiol concentrations, aiding in disease diagnosis and treatment while also facilitating the exploration of fundamental biological processes. However, the probes are limited by the short fluorescence emission wavelength and small Stokes shift, which makes them susceptible to background fluorescence interference and significant self-absorption. To overcome these limitations and achieve high-fidelity biothiols detection in complex biological systems, this study focuses on developing a near-infrared fluorescent probe with an extended Stokes shift.
Methods
(E)-4-(5-(2-(4-(dicyanomethylene)-4H-chromen-2-yl)vinyl)thiophen-2-yl)phenyl 2,4-dinitrobenzenesulfonate (DCMOS-N), a near-infrared (NIR) fluorescent probe featuring a large Stokes shift, was designed and synthesized for biothiols detection. The optical properties of DCMOS-N were evaluated using ultraviolet-visible (UV-Vis) and fluorescence spectroscopy. Additionally, its imaging capabilities for detecting biothiols in living cells were assessed through confocal fluorescence microscopy.
Results
Fluorescence spectral analysis confirmed that the DCMOS-N probe exhibits high selectivity and strong anti-interference properties in biothiol detection. Moreover, its fluorescence intensity increases upon the addition of biothiols. Notably, a strong linear correlation was observed across the concentration range of 0 to 100 μmol/L (R2 = 0.9944 for glutathione (GSH), 0.9942 for cysteine (Cys), and 0.9946 for homocysteine (Hcy)), enabling the quantitative analysis of biothiol concentrations in biological systems. The detection limits for GSH, Cys, and Hcy were determined as 0.142 μmol/L, 0.129 μmol/L, and 0.143 μmol/L, respectively. Importantly, the practical application of DCMOS-N in living cells was validated, with confocal fluorescence imaging demonstrating its capability to detect both endogenous and exogenous biothiols in HeLa cells.
Conclusion
An NIR fluorescent probe, DCMOS-N, was developed and effectively utilized to monitor biothiols in living HeLa cells. The successful design of DCMOS-N presents significant potential and serves as an innovative platform for developing fluorescence probes targeted at biothiols.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Shaanxi Key Laboratory of Chemical Additives for Industry, College of Chemistry and Chemical Engineering, Shaanxi University of Science & Technology, 710021 Xi'an, Shaanxi, China.
Förderung
- Science and Technology Plan Project of Xi'an
- Science and Technology Plan Project of Weiyang District
- Science and Technology Plan Project of Xi’an
Zitieren
APA
Li, X., Yuan, R., Ma, Y., Li, G., & Ma, S. (2025). A Highly Selective and Sensitive Fluorescent Probe With a Large Stokes Shift for Near-Infrared Visualization of Endogenous and Exogenous Biothiols in Living Cells. Frontiers in Bioscience-Landmark. https://doi.org/10.31083/fbl37240
Vancouver
Li X, Yuan R, Ma Y, Li G, Ma S. A Highly Selective and Sensitive Fluorescent Probe With a Large Stokes Shift for Near-Infrared Visualization of Endogenous and Exogenous Biothiols in Living Cells. Frontiers in Bioscience-Landmark. 2025. doi:10.31083/fbl37240
BibTeX
@article{Li2025,
author = {Li, Xiaomin and Yuan, Rongrong and Ma, Yangmin and Li, Guanglong and Ma, Siyue},
title = {A Highly Selective and Sensitive Fluorescent Probe With a Large Stokes Shift for Near-Infrared Visualization of Endogenous and Exogenous Biothiols in Living Cells},
journal = {Frontiers in Bioscience-Landmark},
year = {2025},
doi = {10.31083/fbl37240}
}
EUVIMED