EUVIMEDEUVIMED entdecken
Crossref

HPLC METHOD DEVELOPMENT AND VALIDATION FOR AZITHRO-MYCIN IN ORAL SUSPENSION

Alok Pratap Singh, Iti Chauhan, Snigdha Bhardwaj, Praveen Gaur, S Sadish Kumar, Jayendra J

Journal of Applied Pharmaceutical Sciences and Research · 2019

DOI: 10.31069/japsr.v2i1.2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Pharmaceutical Sciences and Research, 2019. Verfasst von Alok Pratap Singh und 5 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Azithro-mycin a semi-synthetic, azalide congener of erythro-mycin indicated in the treatment of respiratory tract infections. Various methods available for determination of Azithro-mycin, but HPLC are most versatile one.

Objective

The present study is based on the development and validation of a rapid, simple high performance liquid chromatography (HPLC) method equipped with UV detector for quantitative analysis of Azithro-mycin (AZN) in suspension. Material and methods: The Method was performed by using Hypersil BDS-C18 (250 mm × 4.6 mm i.d.) column MS-II, with an isocratic mobile phase of methanol, acetonitrile and phosphate buffer pH 8 (60:30:10; v/v) with run time 15 minutes. The determinations were performed at a flow rate of 1.0ml/min, and UV detector set at 212 nm. Result and Discussion: The method was found to be specific with relative standard deviation (RSD) less than 2.09%. The method showed accuracy with RSD less than 1.34% and precision in repeatability with RSD less than 1.42%. The method was found to be linear over a wide range of concentration from 1.0 to 50.0 μg/mL (R2 = .995). Limit of detection and limit of quantification were found to be 14.40 ng/mL and 43.66 ng/mL respectively.

Conclusion

It was advantageous to use UV detector over other methods employing electrochemical, photodiode array etc. as the detector, because of cheap and easy availability. The developed method fulfilled all validation parameters as per ICH and can be successfully applied to quantify percent drug content in marketed oral Azithro-mycin suspension.

Zitieren

APA

Singh, A. P., Chauhan, I., Bhardwaj, S., Gaur, P., Kumar, S. S., & J, J. (2019). HPLC METHOD DEVELOPMENT AND VALIDATION FOR AZITHRO-MYCIN IN ORAL SUSPENSION. Journal of Applied Pharmaceutical Sciences and Research. https://doi.org/10.31069/japsr.v2i1.2

Vancouver

Singh AP, Chauhan I, Bhardwaj S, Gaur P, Kumar SS, J J. HPLC METHOD DEVELOPMENT AND VALIDATION FOR AZITHRO-MYCIN IN ORAL SUSPENSION. Journal of Applied Pharmaceutical Sciences and Research. 2019. doi:10.31069/japsr.v2i1.2

BibTeX
@article{Singh2019,
  author = {Singh, Alok Pratap and Chauhan, Iti and Bhardwaj, Snigdha and Gaur, Praveen and Kumar, S Sadish and J, Jayendra},
  title = {HPLC METHOD DEVELOPMENT AND VALIDATION FOR AZITHRO-MYCIN IN ORAL SUSPENSION},
  journal = {Journal of Applied Pharmaceutical Sciences and Research},
  year = {2019},
  doi = {10.31069/japsr.v2i1.2}
}
Kostenlos starten →