EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

A laboratory-scale 3-axis automated storage and retrieval system prototype for electronic component management

Sri Kusumastuti, M. Ihya’ Ulumuddin, Cleva Tusara Kumbalany, Sihono Sihono, Vinda Setya Kartika, Raditya Artha Rochmanto, Suryono Suryono, Aminuddin Rizal

Jurnal Polimesin · 26.04.2026 · 24 (2) · 253

DOI: 10.30811/jpl.v24i2.8148 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Jurnal Polimesin, online erschienen am 26.04.2026. Verfasst von Sri Kusumastuti und 7 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Efficient storage and retrieval of electronic components remain challenging in laboratory-scale environments due to reliance on manual handling. This study presents the development and experimental evaluation of a laboratory-scale three-axis Automated Storage and Retrieval System (ASRS) prototype designed for electronic component management. The proposed system uses a combination of servo and stepper motors to provide controlled motion along the X, Y, and Z axes. It is managed by a Programmable Logic Controller (PLC) integrated with a Human–Machine Interface (HMI). Manual operation is used for system calibration and motion adjustment, while automatic operation facilitates sequential storage and retrieval processes. We evaluated the system's performance by measuring positional accuracy and deviation at multiple target rack locations. The results show that the system achieves positioning accuracy of 84.62% - 95.38%, with absolute deviations between 0.3 and 1 cm. These findings demonstrate that the ASRS prototype is a feasible solution for effective laboratory-scale automation in storage applications and for PLC-based educational purposes.

Zitieren

APA

Kusumastuti, S., Ulumuddin, M. I., Kumbalany, C. T., Sihono, S., Kartika, V. S., Rochmanto, R. A., Suryono, S., & Rizal, A. (2026). A laboratory-scale 3-axis automated storage and retrieval system prototype for electronic component management. Jurnal Polimesin, 24(2), 253. https://doi.org/10.30811/jpl.v24i2.8148

Vancouver

Kusumastuti S, Ulumuddin MI, Kumbalany CT, Sihono S, Kartika VS, Rochmanto RA, et al. A laboratory-scale 3-axis automated storage and retrieval system prototype for electronic component management. Jurnal Polimesin. 2026;24(2):253. doi:10.30811/jpl.v24i2.8148

BibTeX
@article{Kusumastuti2026,
  author = {Kusumastuti, Sri and Ulumuddin, M. Ihya’ and Kumbalany, Cleva Tusara and Sihono, Sihono and Kartika, Vinda Setya and Rochmanto, Raditya Artha and Suryono, Suryono and Rizal, Aminuddin},
  title = {A laboratory-scale 3-axis automated storage and retrieval system prototype for electronic component management},
  journal = {Jurnal Polimesin},
  year = {2026},
  volume = {24},
  number = {2},
  pages = {253},
  doi = {10.30811/jpl.v24i2.8148}
}
Kostenlos starten →