EUVIMEDEUVIMED entdecken
Crossref

Behavior of Short Reinforced Concrete Columns Subjected to Eccentric Preloading under Fire Exposure

Mohanad Wisam Mousa, Sarmad Shafeeq Abdulqader, Ahlam Sader Mohammed

Engineering and Technology Journal · 15.03.2026 · 44 (5) · 1-20

DOI: 10.30684/2412-0758.1541 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Engineering and Technology Journal, online erschienen am 15.03.2026. Verfasst von Mohanad Wisam Mousa und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates the fire resistance behavior of square reinforced concrete (RC) columns subjected to a standard ASTM E119 cellulosic fire while carrying a sustained eccentric axial load. Twelve laboratory-scale RC columns were experimentally tested and classified into two groups based on loading eccentricity: Group A with an eccentricity of 45 mm and Group B with an eccentricity of 90 mm. Ten specimens were exposed to fire at target temperatures of 500°C and 700°C for exposure durations of 60 and 120 minutes, while two columns were tested as unexposed reference specimens. Two post-fire cooling methods were considered, namely gradual air cooling and rapid water quenching. After cooling, all specimens were subjected to monotonic axial loading with eccentricity until ultimate failure to evaluate their residual load-carrying capacity. The results indicate that increasing fire temperature and exposure duration significantly reduced the ultimate capacity of fire-exposed columns. Water quenching further intensified strength degradation compared to air cooling. Columns with larger eccentricity exhibited lower residual capacity, highlighting the pronounced interaction between eccentric loading and fire-induced damage. This study addresses the combined effects of eccentric preloading, fire exposure duration, and cooling method on the post-fire performance of RC columns, which have not been investigated simultaneously in previous studies.

Zitieren

APA

Mousa, M. W., Abdulqader, S. S., & Mohammed, A. S. (2026). Behavior of Short Reinforced Concrete Columns Subjected to Eccentric Preloading under Fire Exposure. Engineering and Technology Journal, 44(5), 1-20. https://doi.org/10.30684/2412-0758.1541

Vancouver

Mousa MW, Abdulqader SS, Mohammed AS. Behavior of Short Reinforced Concrete Columns Subjected to Eccentric Preloading under Fire Exposure. Engineering and Technology Journal. 2026;44(5):1-20. doi:10.30684/2412-0758.1541

BibTeX
@article{Mousa2026,
  author = {Mousa, Mohanad Wisam and Abdulqader, Sarmad Shafeeq and Mohammed, Ahlam Sader},
  title = {Behavior of Short Reinforced Concrete Columns Subjected to Eccentric Preloading under Fire Exposure},
  journal = {Engineering and Technology Journal},
  year = {2026},
  volume = {44},
  number = {5},
  pages = {1--20},
  doi = {10.30684/2412-0758.1541}
}