Temperature-dependent behavior of PVA/Drug composites during melt extrusion
Production Engineering Archives · 01.12.2025 · 31 (4) · 526-533
DOI: 10.30657/pea.2025.31.49 ↗Kurz gefasst
Fachartikel in der Zeitschrift Production Engineering Archives, online erschienen am 06.12.2025. Verfasst von Ali AK. Bakly und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 72 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This study highlights the growing collaboration between materials, engineering, and pharmaceutical research, enhancing drug efficacy and reducing side effects by optimizing polymer carriers for stability and compatibility. Polyvinyl alcohol (PVA), Rhumix, glycerol, and citric acid were used as a carrier, drug, plasticizer, and stabilizer to create polymer-drug composites at varying temperatures. A twin-screw extruder was used to mix, melt, and extrude 60% PVA, 30% Rhumix, 9.9% glycerol, and 0.1% citric acid at (160, 170, and 180)°C with a screw speed of 50 rpm. DSC, FTIR, and optical/digital microscopy techniques characterized the composites. Results showed smooth extrusion of the PVA/drug composites, with the addition of plasticizers resulting in lower T g and T m . The extruded compounds exhibited varying colours and surface properties. The bonding values remained stable, indicating no significant interaction. DSC curves revealed two T g values, indicating compatibility and immiscibility. Microscope images demonstrated improved drug dispersion at 160°C. Notably, the selected components, particularly PVA and glycerol, are widely recognised for their biocompatibility and low toxicity, as confirmed by previous studies, which support the potential suitability of these compounds for biomedical applications.
Zitieren
APA
Bakly, A. A., Hadi, N. J., Krynke, M., & Sadiq, M. (2025). Temperature-dependent behavior of PVA/Drug composites during melt extrusion. Production Engineering Archives, 31(4), 526-533. https://doi.org/10.30657/pea.2025.31.49
Vancouver
Bakly AA, Hadi NJ, Krynke M, Sadiq M. Temperature-dependent behavior of PVA/Drug composites during melt extrusion. Production Engineering Archives. 2025;31(4):526-533. doi:10.30657/pea.2025.31.49
BibTeX
@article{Bakly2025,
author = {Bakly, Ali AK. and Hadi, Nizar J. and Krynke, Marek and Sadiq, Mohammed},
title = {Temperature-dependent behavior of PVA/Drug composites during melt extrusion},
journal = {Production Engineering Archives},
year = {2025},
volume = {31},
number = {4},
pages = {526--533},
doi = {10.30657/pea.2025.31.49}
}