EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-SA 4.0

COMPARATIVE EFFECTIVENESS OF MANUAL ULTRASONIC TESTING (UT) AND RADIOGRAPHIC TESTING (RT) FOR WELDING DISCONTINUITIES DETECTION IN CRA CLAD PIPE

Endang Supriyatna, Nur Yanu Nugroho, Didik Hardianto, Bagiyo Suwasono, Bagus Kusuma Aditya

International Journal of Marine Engineering and Applications · 2026

DOI: 10.30649/ijmea.v3i2.404 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Marine Engineering and Applications, 2026. Verfasst von Endang Supriyatna und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The integrity of Dissimilar Metal Welded (DMW) joints in Corrosion Resistant Alloy (CRA) clad pipes is critical for offshore infrastructure. However, the highly anisotropic, coarse-grained dendritic structure of austenitic Inconel 625 overlays causes severe acoustic attenuation and scattering, rendering conventional shear wave testing ineffective. This study evaluates a Manual Ultrasonic Testing (MUT) methodology utilizing 4 MHz focused longitudinal waves and dual-element (TRL) probes to penetrate these metallurgical boundaries. A 28-inch API 5L X65/Inconel 625 clad pipe mockup (60.57 mm total thickness) featuring 9 fabricated discontinuities (EDM notches and volumetric targets) was inspected and cross-validated against Radiographic Testing (RT). MUT achieved a 100% detection rate, correctly sizing internal flaws such as Flaw 7 (cluster porosity: 2–7 mm depth, 21 mm length, 3 mm height), which RT (88.9% detection rate) failed to identify due to geometric thickness limitations and 2D projection constraints. The optimized MUT configuration consistently achieved a Signal-to-Noise Ratio (SNR) ≥ 3:1 (≥ 6 dB), with structural noise floor levels maintained between 13% and 30% of Full Screen Height (FSH). By providing precise 3D spatial localization and vertical height profiling capabilities absent in RT. This study validates that the proposed MUT methodology satisfies the strict compliance criteria of DNVGL-ST-F101 and ASME Section V.

Zitieren

APA

Supriyatna, E., Nugroho, N. Y., Hardianto, D., Suwasono, B., & Aditya, B. K. (2026). COMPARATIVE EFFECTIVENESS OF MANUAL ULTRASONIC TESTING (UT) AND RADIOGRAPHIC TESTING (RT) FOR WELDING DISCONTINUITIES DETECTION IN CRA CLAD PIPE. International Journal of Marine Engineering and Applications. https://doi.org/10.30649/ijmea.v3i2.404

Vancouver

Supriyatna E, Nugroho NY, Hardianto D, Suwasono B, Aditya BK. COMPARATIVE EFFECTIVENESS OF MANUAL ULTRASONIC TESTING (UT) AND RADIOGRAPHIC TESTING (RT) FOR WELDING DISCONTINUITIES DETECTION IN CRA CLAD PIPE. International Journal of Marine Engineering and Applications. 2026. doi:10.30649/ijmea.v3i2.404

BibTeX
@article{Supriyatna2026,
  author = {Supriyatna, Endang and Nugroho, Nur Yanu and Hardianto, Didik and Suwasono, Bagiyo and Aditya, Bagus Kusuma},
  title = {COMPARATIVE EFFECTIVENESS OF MANUAL ULTRASONIC TESTING (UT) AND RADIOGRAPHIC TESTING (RT) FOR WELDING DISCONTINUITIES DETECTION IN CRA CLAD PIPE},
  journal = {International Journal of Marine Engineering and Applications},
  year = {2026},
  doi = {10.30649/ijmea.v3i2.404}
}
Kostenlos starten →