EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Assessing the Impacts of Cemetery on Soil and Groundwater around the St. Peter Anglican Church’s Cemetery, Ikere-Ekiti, Southwestern Nigeria

Abel Ojo Talabi, Ajayi Christopher, Olagoke Oluwatoyin Akinola

Journal of Environmental & Earth Sciences · 13.04.2026 · 117-129

DOI: 10.30564/jees.v8i4.13160 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Environmental & Earth Sciences, online erschienen am 13.04.2026. Verfasst von Abel Ojo Talabi und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluated the effects of St. Peter Anglican Church’s Cemetery, Ikere-Ekiti, Southwestern Nigeria, on surrounding soils and groundwater using a Two-Dimensional (2-D) Electrical Resistivity Tomography (ERT), measured physical characteristics of selected 25 wells’ water and a standardized sanitary survey checklist of the wells. Wells’ locations were captured employing an eTrex 12 Channel Global Positioning System (GPS). Subsequently, in-situ parameters (temperature (℃), electric conductivity (EC (µS/cm)) and pH) were measured using a multiparameter portable meter (model Testr-35). Sanitary inspection revealed substantial variation in protective infrastructures. Thirteen of the twenty-five wells lacked cement bases, only one well (Well 25) was fenced, and a few wells near the cemetery exhibited marshy surroundings and inadequate covering, resulting in risk scores ranging from 20% to 50%. Measured in-situ parameters revealed that the pH ranged from 6.49–7.21, EC from 88–687 μS/cm, and Total Dissolved Solids (TDS) from 44–343 mg/L. All physical parameters had values within the approved World Health Organization (WHO) standard for drinking water. The result of the ERT revealed that the leachate from the cemetery has accumulated within stations 15 and 19 (distances 75–95 m) to a depth of about 2.5 to 25 m around the South-Western part of Traverse 1. Traces of the leachates were observed around stations 7 to 9 within a depth range of 0–7.5 m along the North-Eastern part of Traverse 2. Overall, the results showed that the quality of groundwater is suitable for domestic use, as most wells have good infrastructure built up that prevented percolation of leachates.

Zitieren

APA

Talabi, A. O., Christopher, A., & Akinola, O. O. (2026). Assessing the Impacts of Cemetery on Soil and Groundwater around the St. Peter Anglican Church’s Cemetery, Ikere-Ekiti, Southwestern Nigeria. Journal of Environmental & Earth Sciences, 117-129. https://doi.org/10.30564/jees.v8i4.13160

Vancouver

Talabi AO, Christopher A, Akinola OO. Assessing the Impacts of Cemetery on Soil and Groundwater around the St. Peter Anglican Church’s Cemetery, Ikere-Ekiti, Southwestern Nigeria. Journal of Environmental & Earth Sciences. 2026:117-129. doi:10.30564/jees.v8i4.13160

BibTeX
@article{Talabi2026,
  author = {Talabi, Abel Ojo and Christopher, Ajayi and Akinola, Olagoke Oluwatoyin},
  title = {Assessing the Impacts of Cemetery on Soil and Groundwater around the St. Peter Anglican Church’s Cemetery, Ikere-Ekiti, Southwestern Nigeria},
  journal = {Journal of Environmental & Earth Sciences},
  year = {2026},
  pages = {117--129},
  doi = {10.30564/jees.v8i4.13160}
}
Kostenlos starten →