Evaluation of CMU Shear Walls Using Digital Image Correlation

Brittany Bullard, Michael Gangone, Michael McGinnis

Journal of Building Material Science · 05.08.2026 · 64-83

DOI: 10.30564/jbms.v8i3.13405 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Building Material Science, online erschienen am 05.08.2026. Verfasst von Brittany Bullard und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Throughout recorded history, masonry has played a significant role in the construction of structures across diverse cultures and geographic regions. In the last century, concrete masonry units (CMU) have effectively replaced traditional red brick in masonry in the US with the exception of some veneer purposes. CMU structures are significantly stronger than traditional masonry and have a wide variety of uses, with walls being the most common application. The research presented here investigates the differences in failure behavior of CMU shear walls with varying horizontal joint reinforcement configurations. Existing literature acknowledges that horizontal joint reinforcement is key to shear strength in masonry walls, but no research was identified that experimentally tests shear walls with spliced joint reinforcement. Two CMU walls were tested in quasi-static unidirectional lateral pushover, one with continuous joint reinforcement and one with spliced joint reinforcement. To evaluate specimen behavior, digital image correlation (DIC) was utilized as the primary measurement tool, revealing previously unobserved aspects of cracking patterns and their relationship to reinforcement splice regions. Analysis of the test results showed that walls containing uninterrupted joint reinforcement were capable of sustaining larger maximum loads and maintained a more ductile response after reaching peak capacity. Additionally, the presence of reinforcement splices was associated with elevated strain measurements occurring at numerous locations within the wall system.

Zitieren

APA

Bullard, B., Gangone, M., & McGinnis, M. (2026). Evaluation of CMU Shear Walls Using Digital Image Correlation. Journal of Building Material Science, 64-83. https://doi.org/10.30564/jbms.v8i3.13405

Vancouver

Bullard B, Gangone M, McGinnis M. Evaluation of CMU Shear Walls Using Digital Image Correlation. Journal of Building Material Science. 2026:64-83. doi:10.30564/jbms.v8i3.13405

BibTeX
@article{Bullard2026,
  author = {Bullard, Brittany and Gangone, Michael and McGinnis, Michael},
  title = {Evaluation of CMU Shear Walls Using Digital Image Correlation},
  journal = {Journal of Building Material Science},
  year = {2026},
  pages = {64--83},
  doi = {10.30564/jbms.v8i3.13405}
}
Kostenlos starten →