Differences in Cervical Extensor Muscles Thickness on Subjects with Normal Head Posture and Forward Head Posture: An Ultrasonography Study
Journal of rehabilitation sciences and research · 01.06.2015 · 2 (2) · 23-26
DOI: 10.30476/jrsr.2015.41069 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of rehabilitation sciences and research, erschienen am 01.06.2015. Verfasst von Fereshte Goodarzi und 3 weiteren Autor:innen. Die Arbeit wurde bisher 13-mal zitiert (Crossref).
Abstract (Originalsprache)
Background
Forward head posture (FHP) is recognized as a common postural disorder of modern societies. Increase in anterior cervical convexity and anterior displacement of the line of gravity of head in individuals with FHP is assumed to result in altered moment arms and muscle activity on cervical spine. Measurement of muscle thickness seems to be an appropriate index for muscle activity. This study was aimed to compare cervical extensor muscle thickness in individuals with normal head posture with those suffering from FHP.
Methods
Twenty volunteers with FHP and 20 matched controls (11 females and 9 males in each group) participated in this cross-sectional study. The thickness of cervical extensor muscles including multifidus, semispinalis cervicis, semispinalis capitis, splenius capitis and upper trapezius were measured using ultrasonography at the level of forth cervical vertebrae at rest.
Results
No significant differences of thickness of cervical extensor muscles were observed between the two groups (p
Schlagwörter
Zitieren
APA
Goodarzi, F., Karimi, N., Rahnama, L., & Khodakarim, L. (2015). Differences in Cervical Extensor Muscles Thickness on Subjects with Normal Head Posture and Forward Head Posture: An Ultrasonography Study. Journal of rehabilitation sciences and research, 2(2), 23-26. https://doi.org/10.30476/jrsr.2015.41069
Vancouver
Goodarzi F, Karimi N, Rahnama L, Khodakarim L. Differences in Cervical Extensor Muscles Thickness on Subjects with Normal Head Posture and Forward Head Posture: An Ultrasonography Study. Journal of rehabilitation sciences and research. 2015;2(2):23-26. doi:10.30476/jrsr.2015.41069
BibTeX
@article{Goodarzi2015,
author = {Goodarzi, Fereshte and Karimi, Noureddin and Rahnama, Leila and Khodakarim, Leila},
title = {Differences in Cervical Extensor Muscles Thickness on Subjects with Normal Head Posture and Forward Head Posture: An Ultrasonography Study},
journal = {Journal of rehabilitation sciences and research},
year = {2015},
volume = {2},
number = {2},
pages = {23--26},
doi = {10.30476/jrsr.2015.41069}
}
EUVIMED