Mass Dose Effects in FAP-Directed Imaging: Influence of Administered Dose of [ 68 Ga]Ga-LNTH-1363S on Image Quality
Journal of Nuclear Medicine · 2026
DOI: 10.2967/jnumed.125.271511 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Nuclear Medicine, 2026. Verfasst von Johanna S Enke und 11 weiteren Autor:innen. Beteiligte Einrichtung: Nuclear Medicine, Faculty of Medicine, University of Augsburg, Augsburg, Germany. Hauptthemen laut MEDLINE: Gallium Radioisotopes, Membrane Proteins, Serine Endopeptidases, Gelatinases. Die Arbeit nennt 16 Literaturangaben.
Abstract (Originalsprache)
Recent advances in fibroblast activation protein imaging have led to the development of new fibroblast activation protein-targeting radiotracers. This study investigates the mass dose effects of [68Ga]Ga-LNTH-1363S on image quality.
Methods
In this retrospective evaluation of 39 patients with various oncologic diseases (including breast cancer and sarcoma), different administered mass doses (30, 75, 90, and 100 μg) of [68Ga]Ga-LNTH-1363S were visually and quantitatively (blood pool SUVmean, lesion SUVmax, and tumor-to-blood pool ratios [TBRs]) assessed.
Results
Lower peptide masses were associated with prominent blood pooling in [68Ga]Ga-LNTH-1363S PET imaging and reduced TBRs, whereas higher mass doses yielded superior image quality because of lower mean tracer accumulation in the blood pool and therefore higher TBRs.
Conclusion
These observations provide evidence that biodistribution and imaging quality are dependent on the administered mass dose. Further studies are warranted to validate these findings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Nuclear Medicine, Faculty of Medicine, University of Augsburg, Augsburg, Germany.
- Bavarian Cancer Research Center, Augsburg, Germany.
- Lantheus, Bedford, Massachusetts.
- Hematology and Oncology, Faculty of Medicine, University of Augsburg, Augsburg, Germany; and.
- Ratio Therapeutics, Boston, Massachusetts.
- Nuclear Medicine, Faculty of Medicine, University of Augsburg, Augsburg, Germany; constantin.lapa@uk-augsburg.de.
Zitieren
APA
Enke, J. S., Baessler, J., Chand, G., Glantschnig, L., Bai, B., Sjoestrand, K., Trepel, M., Orcutt, K., Dreher, N., Patt, M., Dierks, A., & Lapa, C. (2026). Mass Dose Effects in FAP-Directed Imaging: Influence of Administered Dose of [ 68 Ga]Ga-LNTH-1363S on Image Quality. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.125.271511
Vancouver
Enke JS, Baessler J, Chand G, Glantschnig L, Bai B, Sjoestrand K, et al. Mass Dose Effects in FAP-Directed Imaging: Influence of Administered Dose of [ 68 Ga]Ga-LNTH-1363S on Image Quality. Journal of Nuclear Medicine. 2026. doi:10.2967/jnumed.125.271511
BibTeX
@article{Enke2026,
author = {Enke, Johanna S and Baessler, Jan and Chand, Gitasha and Glantschnig, Lisa and Bai, Bing and Sjoestrand, Karl and Trepel, Martin and Orcutt, Kelly and Dreher, Niklas and Patt, Marianne and Dierks, Alexander and Lapa, Constantin},
title = {Mass Dose Effects in FAP-Directed Imaging: Influence of Administered Dose of [ 68 Ga]Ga-LNTH-1363S on Image Quality},
journal = {Journal of Nuclear Medicine},
year = {2026},
doi = {10.2967/jnumed.125.271511}
}
EUVIMED