Deep Learning for Automated Measures of SUV and Molecular Tumor Volume in [ 68 Ga]PSMA-11 or [ 18 F]DCFPyL, [ 18 F]FDG, and [ 177 Lu]Lu-PSMA-617 Imaging with Global Threshold Regional Consensus Network
Journal of Nuclear Medicine · 2025
DOI: 10.2967/jnumed.125.270077 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Nuclear Medicine, 2025. Verfasst von Price Jackson und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne, Australia; price.jackson@petermac.org. Hauptthemen laut MEDLINE: Deep Learning, Fluorodeoxyglucose F18, Dipeptides, Tumor Burden. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
Metastatic castration-resistant prostate cancer has a high rate of mortality with a limited number of effective treatments after hormone therapy. Radiopharmaceutical therapy with [177Lu]Lu-prostate-specific membrane antigen-617 (LuPSMA) is one treatment option; however, response varies and is partly predicted by PSMA expression and metabolic activity, assessed on [68Ga]PSMA-11 or [18F]DCFPyL and [18F]FDG PET, respectively. Automated methods to measure these on PET imaging have previously yielded modest accuracy. Refining computational workflows and standardizing approaches may improve patient selection and prognostication for LuPSMA therapy.
Methods
PET/CT and quantitative SPECT/CT images from an institutional cohort of patients staged for LuPSMA therapy were annotated for total disease burden. In total, 676 [68Ga]PSMA-11 or [18F]DCFPyL PET, 390 [18F]FDG PET, and 477 LuPSMA SPECT images were used for development of automated workflow and tested on 56 cases with externally referred PET/CT staging. A segmentation framework, the Global Threshold Regional Consensus Network, was developed based on nnU-Net, with processing refinements to improve boundary definition and overall label accuracy.
Results
Using the model to contour disease extent, the mean volumetric Dice similarity coefficient for [68Ga]PSMA-11 or [18F]DCFPyL PET was 0.94, for [18F]FDG PET was 0.84, and for LuPSMA SPECT was 0.97. On external test cases, Dice accuracy was 0.95 and 0.84 on PSMA and FDG PET, respectively. The refined models yielded consistent improvements compared with nnU-Net, with an increase of 3%-5% in Dice accuracy and 10%-17% in surface agreement. Quantitative biomarkers were compared with a human-defined ground truth using the Pearson coefficient, with scores for [68Ga]PSMA-11 or [18F]DCFPyL, [18F]FDG, and LuPSMA, respectively, of 0.98, 0.94, and 0.99 for disease volume; 0.98, 0.88, and 0.99 for SUVmean; 0.96, 0.91, and 0.99 for SUVmax; and 0.97, 0.96, and 0.99 for volume intensity product.
Conclusion
Delineation of disease extent and tracer avidity can be performed with a high degree of accuracy using automated deep learning methods. By incorporating threshold-based postprocessing, the tools can closely match the output of manual workflows. Pretrained models and scripts to adapt to institutional data are provided for open use.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne, Australia; price.jackson@petermac.org.
- Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Australia; and.
- Department of Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne, Australia.
- Department of Physics, RMIT University, Melbourne, Australia.
Zitieren
APA
Jackson, P., Buteau, J. P., McIntosh, L., Sun, Y., Kashyap, R., Casanueva, S., Ravi Kumar, A. S., Sandhu, S., Azad, A. A., Alipour, R., Saghebi, J., Kong, G., Jewell, K., Eifer, M., Bollampally, N., & Hofman, M. S. (2025). Deep Learning for Automated Measures of SUV and Molecular Tumor Volume in [ 68 Ga]PSMA-11 or [ 18 F]DCFPyL, [ 18 F]FDG, and [ 177 Lu]Lu-PSMA-617 Imaging with Global Threshold Regional Consensus Network. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.125.270077
Vancouver
Jackson P, Buteau JP, McIntosh L, Sun Y, Kashyap R, Casanueva S, et al. Deep Learning for Automated Measures of SUV and Molecular Tumor Volume in [ 68 Ga]PSMA-11 or [ 18 F]DCFPyL, [ 18 F]FDG, and [ 177 Lu]Lu-PSMA-617 Imaging with Global Threshold Regional Consensus Network. Journal of Nuclear Medicine. 2025. doi:10.2967/jnumed.125.270077
BibTeX
@article{Jackson2025,
author = {Jackson, Price and Buteau, James P and McIntosh, Lachlan and Sun, Yu and Kashyap, Raghava and Casanueva, Sebastian and Ravi Kumar, Aravind S and Sandhu, Shahneen and Azad, Arun A and Alipour, Ramin and Saghebi, Javad and Kong, Grace and Jewell, Kerry and Eifer, Michal and Bollampally, Neeraja and Hofman, Michael S},
title = {Deep Learning for Automated Measures of SUV and Molecular Tumor Volume in [ 68 Ga]PSMA-11 or [ 18 F]DCFPyL, [ 18 F]FDG, and [ 177 Lu]Lu-PSMA-617 Imaging with Global Threshold Regional Consensus Network},
journal = {Journal of Nuclear Medicine},
year = {2025},
doi = {10.2967/jnumed.125.270077}
}
EUVIMED