Comparability of Quantifying Relative Lung Ventilation with Inhaled 99m Tc-Technegas and 133 Xe in Patients Undergoing Evaluation for Lung Transplantation
Journal of Nuclear Medicine · 2025
DOI: 10.2967/jnumed.124.268801 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Nuclear Medicine, 2025. Verfasst von Ashwin Singh Parihar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Nuclear Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri ashwinp@wustl.edu. Hauptthemen laut MEDLINE: Lung Transplantation, Pulmonary Ventilation. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
99mTc-Technegas was recently approved by the U.S. Food and Drug Administration as a radiopharmaceutical for ventilation scintigraphy. However, there are currently no data comparing the quantification of relative lung ventilation with 99mTc-Technegas with that performed using the standard approach with inhaled 133Xe.
Methods
We performed a secondary analysis of data from prospectively recruited participants in a phase 3 trial undergoing evaluation for lung transplantation who received both 133Xe and 99mTc-Technegas ventilation imaging. The 133Xe and 99mTc-Technegas images were analyzed asynchronously using semiautomatic segmentation to extract the relative lung ventilation percentages. The anterior and posterior 99mTc-Technegas images were analyzed to derive 3 sets of relative ventilation percentages (posterior, anterior, and geometric mean data) and compared with the values from posterior 133Xe images. We evaluated for correlation and agreement between the relative lung ventilation percentages obtained using these 2 radiopharmaceuticals.
Results
In a cohort of 74 participants, we found a strong positive correlation in the relative lung ventilation quantified using 133Xe with that using 99mTc-Technegas. A high level of agreement was demonstrated on the Bland-Altman plot comparing the 2 imaging modalities. Seventy-two of 74 participants (97.3%) had their relative ventilation percentage measurements within ±15% for 133Xe and 99mTc-Technegas. The differences in relative ventilation measurements were within the 95% CI limits of the mean for 70 of 74 participants (94.6%) and within a narrower ±10% threshold for 68 of 74 participants (91.9%), again reflecting the comparability of the 2 techniques. The strongest correlation coefficient (r = 0.79) was observed between the relative ventilation percentages obtained from 133Xe and posterior 99mTc-Technegas images. The geometric mean method had a slightly lower but still comparable correlation (r = 0.77), and as expected, the correlation with the anterior 99mTc-Technegas images was worst (r = 0.70).
Conclusion
We showed a strong positive correlation and high agreement between the relative lung ventilation percentages obtained using 133Xe and 99mTc-Technegas. These data provide important clinical evidence supporting the use of 99mTc-Technegas for quantification of relative lung ventilation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Nuclear Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri ashwinp@wustl.edu.
- Division of Nuclear Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri.
Zitieren
APA
Parihar, A. S., Mhlanga, J. C., Royal, H. D., & Siegel, B. A. (2025). Comparability of Quantifying Relative Lung Ventilation with Inhaled 99m Tc-Technegas and 133 Xe in Patients Undergoing Evaluation for Lung Transplantation. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.124.268801
Vancouver
Parihar AS, Mhlanga JC, Royal HD, Siegel BA. Comparability of Quantifying Relative Lung Ventilation with Inhaled 99m Tc-Technegas and 133 Xe in Patients Undergoing Evaluation for Lung Transplantation. Journal of Nuclear Medicine. 2025. doi:10.2967/jnumed.124.268801
BibTeX
@article{Parihar2025,
author = {Parihar, Ashwin Singh and Mhlanga, Joyce C and Royal, Henry D and Siegel, Barry A},
title = {Comparability of Quantifying Relative Lung Ventilation with Inhaled 99m Tc-Technegas and 133 Xe in Patients Undergoing Evaluation for Lung Transplantation},
journal = {Journal of Nuclear Medicine},
year = {2025},
doi = {10.2967/jnumed.124.268801}
}