Improving 18 F-FDG PET Quantification Through a Spatial Normalization Method

Daewoon Kim, Seung Kwan Kang, Seong A Shin, Hongyoon Choi, Jae Sung Lee

Journal of Nuclear Medicine · 2024

DOI: 10.2967/jnumed.123.267360 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Nuclear Medicine, 2024. Verfasst von Daewoon Kim und 4 weiteren Autor:innen. Beteiligte Einrichtung: Interdisciplinary Program of Bioengineering, Seoul National University, Seoul, South Korea. Hauptthemen laut MEDLINE: Fluorodeoxyglucose F18, Positron-Emission Tomography, Image Processing, Computer-Assisted, Brain. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantification of 18F-FDG PET images is useful for accurate diagnosis and evaluation of various brain diseases, including brain tumors, epilepsy, dementia, and Parkinson disease. However, accurate quantification of 18F-FDG PET images requires matched 3-dimensional T1 MRI scans of the same individuals to provide detailed information on brain anatomy. In this paper, we propose a transfer learning approach to adapt a pretrained deep neural network model from amyloid PET to spatially normalize 18F-FDG PET images without the need for 3-dimensional MRI.

Methods

The proposed method is based on a deep learning model for automatic spatial normalization of 18F-FDG brain PET images, which was developed by fine-tuning a pretrained model for amyloid PET using only 103 18F-FDG PET and MR images. After training, the algorithm was tested on 65 internal and 78 external test sets. All T1 MR images with a 1-mm isotropic voxel size were processed with FreeSurfer software to provide cortical segmentation maps used to extract a ground-truth regional SUV ratio using cerebellar gray matter as a reference region. These values were compared with those from spatial normalization-based quantification methods using the proposed method and statistical parametric mapping software.

Results

The proposed method showed superior spatial normalization compared with statistical parametric mapping, as evidenced by increased normalized mutual information and better size and shape matching in PET images. Quantitative evaluation revealed a consistently higher SUV ratio correlation and intraclass correlation coefficients for the proposed method across various brain regions in both internal and external datasets. The remarkably good correlation and intraclass correlation coefficient values of the proposed method for the external dataset are noteworthy, considering the dataset's different ethnic distribution and the use of different PET scanners and image reconstruction algorithms.

Conclusion

This study successfully applied transfer learning to a deep neural network for 18F-FDG PET spatial normalization, demonstrating its resource efficiency and improved performance. This highlights the efficacy of transfer learning, which requires a smaller number of datasets than does the original network training, thus increasing the potential for broader use of deep learning-based brain PET spatial normalization techniques for various clinical and research radiotracers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorodeoxyglucose F18Positron-Emission TomographyImage Processing, Computer-AssistedBrainHumansMaleFemaleDeep LearningMagnetic Resonance ImagingMiddle AgedAged

Stichwörter der Autor:innen

brain PETglucose metabolismquantificationspatial normalization

Substanzen

Fluorodeoxyglucose F18

Autor:innen und Institutionen

  • Interdisciplinary Program of Bioengineering, Seoul National University, Seoul, South Korea.
  • Artificial Intelligence Institute, Seoul National University, Seoul, South Korea.
  • Brightonix Imaging Inc., Seoul, South Korea; jaes@snu.ac.kr kevin.kang@brtnx.com.
  • Institute of Radiation Medicine, Medical Research Center, Seoul National University College of Medicine, Seoul, South Korea; and.
  • Brightonix Imaging Inc., Seoul, South Korea.
  • Department of Nuclear Medicine, Seoul National University College of Medicine and Seoul National University Hospital, Seoul, South Korea.

Zitieren

APA

Kim, D., Kang, S. K., Shin, S. A., Choi, H., & Lee, J. S. (2024). Improving 18 F-FDG PET Quantification Through a Spatial Normalization Method. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.123.267360

Vancouver

Kim D, Kang SK, Shin SA, Choi H, Lee JS. Improving 18 F-FDG PET Quantification Through a Spatial Normalization Method. Journal of Nuclear Medicine. 2024. doi:10.2967/jnumed.123.267360

BibTeX
@article{Kim2024,
  author = {Kim, Daewoon and Kang, Seung Kwan and Shin, Seong A and Choi, Hongyoon and Lee, Jae Sung},
  title = {Improving 18 F-FDG PET Quantification Through a Spatial Normalization Method},
  journal = {Journal of Nuclear Medicine},
  year = {2024},
  doi = {10.2967/jnumed.123.267360}
}
Kostenlos starten →