EUVIMEDEUVIMED entdecken
Open Access

High-Temporal-Resolution Kinetic Modeling of Lung Tumors with Dual-Blood Input Function Using Total-Body Dynamic PET

Yiran Wang, Yasser G Abdelhafez, Benjamin A Spencer, Rashmi Verma, Mamta Parikh, Nicholas Stollenwerk, Lorenzo Nardo, Terry Jones, Ramsey D Badawi, Simon R Cherry, Guobao Wang

Journal of Nuclear Medicine · 2024

DOI: 10.2967/jnumed.123.267036 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Nuclear Medicine, 2024. Verfasst von Yiran Wang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of California Davis Medical Center, Sacramento, California. Hauptthemen laut MEDLINE: Lung Neoplasms, Positron-Emission Tomography. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NIDDK NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The lungs are supplied by both the pulmonary arteries carrying deoxygenated blood originating from the right ventricle and the bronchial arteries carrying oxygenated blood downstream from the left ventricle. However, this effect of dual blood supply has never been investigated using PET, partially because the temporal resolution of conventional dynamic PET scans is limited. The advent of PET scanners with a long axial field of view, such as the uEXPLORER total-body PET/CT system, permits dynamic imaging with high temporal resolution (HTR). In this work, we modeled the dual-blood input function (DBIF) and studied its impact on the kinetic quantification of normal lung tissue and lung tumors using HTR dynamic PET imaging.

Methods

Thirteen healthy subjects and 6 cancer subjects with lung tumors underwent a dynamic 18F-FDG scan with the uEXPLORER for 1 h. Data were reconstructed into dynamic frames of 1 s in the early phase. Regional time-activity curves of lung tissue and tumors were analyzed using a 2-tissue compartmental model with 3 different input functions: the right ventricle input function, left ventricle input function, and proposed DBIF, all with time delay and dispersion corrections. These models were compared for time-activity curve fitting quality using the corrected Akaike information criterion and for differentiating lung tumors from lung tissue using the Mann-Whitney U test. Voxelwise multiparametric images by the DBIF model were further generated to verify the regional kinetic analysis.

Results

The effect of dual blood supply was pronounced in the high-temporal-resolution time-activity curves of lung tumors. The DBIF model achieved better time-activity curve fitting than the other 2 single-input models according to the corrected Akaike information criterion. The estimated fraction of left ventricle input was low in normal lung tissue of healthy subjects but much higher in lung tumors (∼0.04 vs. ∼0.3, P < 0.0003). The DBIF model also showed better robustness in the difference in 18F-FDG net influx rate [Formula: see text] and delivery rate [Formula: see text] between lung tumors and normal lung tissue. Multiparametric imaging with the DBIF model further confirmed the differences in tracer kinetics between normal lung tissue and lung tumors.

Conclusion

The effect of dual blood supply in the lungs was demonstrated using HTR dynamic imaging and compartmental modeling with the proposed DBIF model. The effect was small in lung tissue but nonnegligible in lung tumors. HTR dynamic imaging with total-body PET can offer a sensitive tool for investigating lung diseases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lung NeoplasmsPositron-Emission TomographyHumansMaleFemaleMiddle AgedKineticsModels, BiologicalAdultFluorodeoxyglucose F18AgedWhole Body ImagingPositron Emission Tomography Computed TomographyImage Processing, Computer-AssistedTime FactorsRadiopharmaceuticals

Stichwörter der Autor:innen

dual-blood input functionhigh temporal resolutionkinetic modelinglung cancertotal-body dynamic PET

Substanzen

Fluorodeoxyglucose F18Radiopharmaceuticals

Autor:innen und Institutionen

  • Department of Radiology, University of California Davis Medical Center, Sacramento, California.
  • Department of Biomedical Engineering, University of California, Davis, Davis, California.
  • Nuclear Medicine Unit, South Egypt Cancer Institute, Assiut University, Assiut, Egypt; and.
  • Comprehensive Cancer Center, University of California Davis Medical Center, Sacramento, California.
  • Department of Radiology, University of California Davis Medical Center, Sacramento, California; gbwang@ucdavis.edu.

Förderung

  • NCI NIH HHS
  • NIDDK NIH HHS

Zitieren

APA

Wang, Y., Abdelhafez, Y. G., Spencer, B. A., Verma, R., Parikh, M., Stollenwerk, N., Nardo, L., Jones, T., Badawi, R. D., Cherry, S. R., & Wang, G. (2024). High-Temporal-Resolution Kinetic Modeling of Lung Tumors with Dual-Blood Input Function Using Total-Body Dynamic PET. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.123.267036

Vancouver

Wang Y, Abdelhafez YG, Spencer BA, Verma R, Parikh M, Stollenwerk N, et al. High-Temporal-Resolution Kinetic Modeling of Lung Tumors with Dual-Blood Input Function Using Total-Body Dynamic PET. Journal of Nuclear Medicine. 2024. doi:10.2967/jnumed.123.267036

BibTeX
@article{Wang2024,
  author = {Wang, Yiran and Abdelhafez, Yasser G and Spencer, Benjamin A and Verma, Rashmi and Parikh, Mamta and Stollenwerk, Nicholas and Nardo, Lorenzo and Jones, Terry and Badawi, Ramsey D and Cherry, Simon R and Wang, Guobao},
  title = {High-Temporal-Resolution Kinetic Modeling of Lung Tumors with Dual-Blood Input Function Using Total-Body Dynamic PET},
  journal = {Journal of Nuclear Medicine},
  year = {2024},
  doi = {10.2967/jnumed.123.267036}
}
Kostenlos starten →