Can Internal Carotid Arteries Be Used for Noninvasive Quantification of Brain PET Studies?
Journal of Nuclear Medicine · 2024-04 · 65 (4) · 600-606
DOI: 10.2967/jnumed.123.266675 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Nuclear Medicine, online erschienen am 14.03.2024. Verfasst von Laura Providência und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands l.lope…. Hauptthemen laut MEDLINE: Carotid Artery, Internal, Positron-Emission Tomography. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
Because of the limited axial field of view of conventional PET scanners, the internal carotid arteries are commonly used to obtain an image-derived input function (IDIF) in quantitative brain PET. However, time-activity curves extracted from the internal carotids are prone to partial-volume effects due to the limited PET resolution. This study aimed to assess the use of the internal carotids for quantifying brain glucose metabolism before and after partial-volume correction.
Methods
Dynamic [18F]FDG images were acquired on a 106-cm-long PET scanner, and quantification was performed with a 2-tissue-compartment model and Patlak analysis using an IDIF extracted from the internal carotids. An IDIF extracted from the ascending aorta was used as ground truth.
Results
The internal carotid IDIF underestimated the area under the curve by 37% compared with the ascending aorta IDIF, leading to Ki values approximately 17% higher. After partial-volume correction, the mean relative Ki differences calculated with the ascending aorta and internal carotid IDIFs dropped to 7.5% and 0.05%, when using a 2-tissue-compartment model and Patlak analysis, respectively. However, microparameters (K 1, k 2, k 3) derived from the corrected internal carotid curve differed significantly from those obtained using the ascending aorta.
Conclusion
These results suggest that partial-volume-corrected internal carotids may be used to estimate Ki but not kinetic microparameters. Further validation in a larger patient cohort with more variable kinetics is needed for more definitive conclusions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands l.lopes.goncalves.da.providencia@umcg.nl.
- Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Zitieren
APA
Providência, L., van der Weijden, C. W. J., Mohr, P., van Sluis, J., van Snick, J. H., Slart, R. H. J. A., Dierckx, R. A. J. O., Lammertsma, A. A., & Tsoumpas, C. (2024). Can Internal Carotid Arteries Be Used for Noninvasive Quantification of Brain PET Studies?. Journal of Nuclear Medicine, 65(4), 600-606. https://doi.org/10.2967/jnumed.123.266675
Vancouver
Providência L, van der Weijden CWJ, Mohr P, van Sluis J, van Snick JH, Slart RHJA, et al. Can Internal Carotid Arteries Be Used for Noninvasive Quantification of Brain PET Studies?. Journal of Nuclear Medicine. 2024;65(4):600-606. doi:10.2967/jnumed.123.266675
BibTeX
@article{Providncia2024,
author = {Providência, Laura and van der Weijden, Chris W J and Mohr, Philipp and van Sluis, Joyce and van Snick, Johannes H and Slart, Riemer H J A and Dierckx, Rudi A J O and Lammertsma, Adriaan A and Tsoumpas, Charalampos},
title = {Can Internal Carotid Arteries Be Used for Noninvasive Quantification of Brain PET Studies?},
journal = {Journal of Nuclear Medicine},
year = {2024},
volume = {65},
number = {4},
pages = {600--606},
doi = {10.2967/jnumed.123.266675}
}
EUVIMED