EUVIMEDEUVIMED entdecken
Open Access

Single-Time-Point Imaging for Dosimetry After [ 177 Lu]Lu-DOTATATE: Accuracy of Existing Methods and Novel Data-Driven Models for Reducing Sensitivity to Time-Point Selection

Chang Wang, Avery B Peterson, Ka Kit Wong, Molly E Roseland, Matthew J Schipper, Yuni K Dewaraja

Journal of Nuclear Medicine · 2023-09 · 64 (9) · 1463-1470

DOI: 10.2967/jnumed.122.265338 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Nuclear Medicine, online erschienen am 27.07.2023. Verfasst von Chang Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biostatistics, University of Michigan, Ann Arbor, Michigan; wangchan@umich.edu. Hauptthemen laut MEDLINE: Octreotide, Organometallic Compounds. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Estimation of the time-integrated activity (TIA) for dosimetry from imaging at a single time point (STP) facilitates the clinical translation of dosimetry-guided radiopharmaceutical therapy. However, the accuracy of the STP methods for TIA estimation varies on the basis of time-point selection. We constructed patient data-driven regression models to reduce the sensitivity to time-point selection and to compare these new models with commonly used STP methods.

Methods

SPECT/CT performed at time period (TP) 1 (3-5 h), TP2 (days 1-2), TP3 (days 3-5), and TP4 (days 6-8) after cycle 1 of [177Lu]Lu-DOTATATE therapy involved 27 patients with 100 segmented tumors and 54 kidneys. Influenced by the previous physics-based STP models of Madsen et al. and Hänscheid et al., we constructed an STP prediction expression, TIA = A(t) × g(t), in a SPECT data-driven way (model 1), in which A(t) is the observed activity at imaging time t, and the curve, g(t), is estimated with a nonparametric generalized additive model by minimizing the normalized mean square error relative to the TIA derived from 4-time-point SPECT (reference TIA). Furthermore, we fit a generalized additive model that incorporates baseline biomarkers as auxiliary data in addition to the single activity measurement (model 2). Leave-one-out cross validation was performed to evaluate STP models using mean absolute error (MAE) and mean square error between the predicted and reference TIA.

Results

At days 3-5, all evaluated STP methods performed very well, with an MAE of less than 7% (between-patient SD of

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OctreotideOrganometallic CompoundsHumansPositron-Emission TomographyRadiometryRadionuclide Imaging

Stichwörter der Autor:innen

177LuDOTATATEdosimetrypeptide receptor radiotherapysingle time pointtheranostics

Substanzen

copper dotatate CU-64OctreotideOrganometallic Compounds

Autor:innen und Institutionen

  • Department of Biostatistics, University of Michigan, Ann Arbor, Michigan; wangchan@umich.edu.
  • Department of Radiology, University of Michigan, Ann Arbor, Michigan.
  • Department of Radiation Oncology, Wayne State University, Detroit, Michigan; and.
  • Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan.

Förderung

  • NCI NIH HHS

Zitieren

APA

Wang, C., Peterson, A. B., Wong, K. K., Roseland, M. E., Schipper, M. J., & Dewaraja, Y. K. (2023). Single-Time-Point Imaging for Dosimetry After [ 177 Lu]Lu-DOTATATE: Accuracy of Existing Methods and Novel Data-Driven Models for Reducing Sensitivity to Time-Point Selection. Journal of Nuclear Medicine, 64(9), 1463-1470. https://doi.org/10.2967/jnumed.122.265338

Vancouver

Wang C, Peterson AB, Wong KK, Roseland ME, Schipper MJ, Dewaraja YK. Single-Time-Point Imaging for Dosimetry After [ 177 Lu]Lu-DOTATATE: Accuracy of Existing Methods and Novel Data-Driven Models for Reducing Sensitivity to Time-Point Selection. Journal of Nuclear Medicine. 2023;64(9):1463-1470. doi:10.2967/jnumed.122.265338

BibTeX
@article{Wang2023,
  author = {Wang, Chang and Peterson, Avery B and Wong, Ka Kit and Roseland, Molly E and Schipper, Matthew J and Dewaraja, Yuni K},
  title = {Single-Time-Point Imaging for Dosimetry After [ 177 Lu]Lu-DOTATATE: Accuracy of Existing Methods and Novel Data-Driven Models for Reducing Sensitivity to Time-Point Selection},
  journal = {Journal of Nuclear Medicine},
  year = {2023},
  volume = {64},
  number = {9},
  pages = {1463--1470},
  doi = {10.2967/jnumed.122.265338}
}
Kostenlos starten →