First Total-Body Kinetic Modeling and Parametric Imaging of Dynamic 68 Ga-FAPI-04 PET in Pancreatic and Gastric Cancer
Journal of Nuclear Medicine · 2023-06 · 64 (6) · 960-967
DOI: 10.2967/jnumed.122.264988 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Nuclear Medicine, online erschienen am 05.01.2023. Verfasst von Ruohua Chen und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Stomach Neoplasms. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
Fibroblast activation protein inhibitor (FAPI) is an ideal diagnostic and therapeutic target in malignant tumors. However, the knowledge of kinetic modeling and parametric imaging of 68Ga-FAPI is limited.
Purpose
The purpose of this study was to explore the pharmacokinetics of 68Ga-FAPI-04 PET/CT in pancreatic cancer and gastric cancer and to conduct parametric imaging of dynamic total-body data compared with SUV imaging.
Methods
Dynamic total-body 68Ga-FAPI-04 PET/CT was performed on 13 patients. The lesion time-activity curves were fitted by 3-compartment models and multigraphical models. The kinetics parameters derived from the 2-tissue reversible compartment model (2T4K) and multigraphical models were analyzed. Parametric [Formula: see text] imaging was generated using the 2T4K and Logan models, and their performances were evaluated compared with SUV images.
Results
2T4K had the lowest Akaike information criterion value, and its fitting curves matched excellently with the origin time-activity curves. Visual assessment revealed that the [Formula: see text](2T4K) images and [Formula: see text](Logan with spatial constraint [SC]) images both showed less image noise and higher lesion conspicuity compared with SUV images. Objective image quality assessment demonstrated that parametric [Formula: see text](2T4K) images and parametric [Formula: see text](Logan with SC) images had a 5.0-fold and 5.0-fold higher average signal-to-noise ratio and 3.6-fold and 4.1-fold higher average contrast-to-noise ratio compared with conventional SUV images, respectively. In addition, no significant differences in signal-to-noise ratio and contrast-to-noise of pathologic lesions were observed between parametric [Formula: see text](2T4K) images and parametric [Formula: see text](Logan with SC) images (all P > 0.05).
Conclusions
The 2T4K model was the preferred compartment model. Total-body parametric imaging of 68Ga-FAPI-04 PET yielded superior quantification beyond SUV with enhanced lesion contrast, which may serve as a promising imaging method to make an early diagnosis, to better reflect tumor characterization, or to allow evaluation of treatment response. [Formula: see text](2T4K) images are comparable in image quality and consistent to [Formula: see text](Logan with SC) images in lesions conspicuity; however, [Formula: see text](Logan with SC) images presented an appealing alternative to [Formula: see text](2T4K) images because of their simplicity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Nuclear Medicine, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
- Institute of Clinical Nuclear Medicine, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
- Shanghai Key Laboratory of Molecular Imaging, Shanghai University of Medicine and Health Sciences, Shanghai, China.
- Central Research Institute, United Imaging Healthcare Group Co., Ltd, Shanghai, China.
- Department of Biliary-Pancreatic Surgery, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China; and.
- Department of Oncology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
Zitieren
APA
Chen, R., Yang, X., Ng, Y. L., Yu, X., Huo, Y., Xiao, X., Zhang, C., Chen, Y., Zheng, C., Li, L., Huang, G., Zhou, Y., & Liu, J. (2023). First Total-Body Kinetic Modeling and Parametric Imaging of Dynamic 68 Ga-FAPI-04 PET in Pancreatic and Gastric Cancer. Journal of Nuclear Medicine, 64(6), 960-967. https://doi.org/10.2967/jnumed.122.264988
Vancouver
Chen R, Yang X, Ng YL, Yu X, Huo Y, Xiao X, et al. First Total-Body Kinetic Modeling and Parametric Imaging of Dynamic 68 Ga-FAPI-04 PET in Pancreatic and Gastric Cancer. Journal of Nuclear Medicine. 2023;64(6):960-967. doi:10.2967/jnumed.122.264988
BibTeX
@article{Chen2023,
author = {Chen, Ruohua and Yang, Xinlan and Ng, Yee Ling and Yu, Xiaofeng and Huo, Yanmiao and Xiao, Xiuying and Zhang, Chenpeng and Chen, Yumei and Zheng, Chaojie and Li, Lianghua and Huang, Gang and Zhou, Yun and Liu, Jianjun},
title = {First Total-Body Kinetic Modeling and Parametric Imaging of Dynamic 68 Ga-FAPI-04 PET in Pancreatic and Gastric Cancer},
journal = {Journal of Nuclear Medicine},
year = {2023},
volume = {64},
number = {6},
pages = {960--967},
doi = {10.2967/jnumed.122.264988}
}
EUVIMED