EUVIMEDEUVIMED entdecken
Crossref

Feasibility of Simulated Low-Count [ 18 F]FDG PET/MR for Patients with Pediatric Epilepsy

RuShuai Li, Feng Wang, Rui Yang, Rui Luo, Xiaoyuan Li, Runze Wu, Jiaxin Hao, Liangshun Xiong, Heping Ju, Shuyue Ai, Lei Xu, Qingle Meng

Journal of Nuclear Medicine Technology · 17.11.2026 · jnmt.126.272511

DOI: 10.2967/jnmt.126.272511 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Nuclear Medicine Technology, online erschienen am 17.11.2026. Verfasst von RuShuai Li und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Nanjing First Hospital, Nanjing Medical University, Nanjing Jiangsu, China; and. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To minimize radiation risks in pediatric PET imaging, injected dose should be kept as low as reasonably achievable. The aim of this study was to explore whether simulated low-count [18F]FDG PET/MR could preserve diagnostic quality in pediatric epilepsy, thereby supporting the design of future lower-activity validation studies.

Methods

Twenty-seven pediatric patients with epilepsy were enrolled. List-mode PET data acquired over 20 min were truncated to 10, 7, and 4 min to simulate count reductions of 50%, 65%, and 80%, respectively. Image quality of the PET images was assessed visually using a 5-point Likert scale and quantitatively using contrast-to-noise ratio and coefficient of variation. The intraclass correlation coefficient was used to evaluate SUV ratio (SUVR) consistency across the simulated count reduction levels in different brain regions. Two computer-assisted methods, region of interest (ROI)–based methods and voxel-based methods, were used for epileptogenic zone (EZ) lateralization. For the ROI-based method, a machine learning model using regional SUVRs as features was applied, and performance was evaluated via receiver-operating-characteristic curve analysis and the area under the curve, with statistical significance assessed by the DeLong test. For the voxel-based method, EZ lateralization was determined on the basis of the hemisphere of hypometabolic clusters identified through asymmetry analysis. Lateralization agreement with the clinical consensus was compared across simulated levels of count reduction.

Results

Quantitative analysis showed that the contrast-to-noise ratio decreased and the coefficient of variation increased significantly with simulated count reduction. Visual assessment indicated that, although overall image quality declined, count reduction up to 65% remained clinically acceptable under these simulated conditions. High consistency in mean SUVRs was observed between full-count and simulated low-count PET images across brain regions. Both ROI-based and voxel-based methods demonstrated that EZ lateralization agreement with the clinical consensus did not decline with simulated count reduction.

Conclusion

Our study in pediatric epilepsy suggests that a 65% simulated count reduction preserved clinically acceptable [18F]FDG PET image quality, stable SUVR quantification, and concordance of EZ lateralization with the clinical consensus. These findings support the need for prospective validation of a low-activity protocol in pediatric epilepsy.

Schlagwörter

Stichwörter der Autor:innen

PET/MRcount reductionimage qualitylateralizationpediatric epilepsy

Autor:innen und Institutionen

  • Department of Nuclear Medicine, Nanjing First Hospital, Nanjing Medical University, Nanjing Jiangsu, China; and.
  • United Imaging Healthcare, Shanghai, China.
  • Department of Nuclear Medicine, Nanjing First Hospital, Nanjing Medical University, Nanjing Jiangsu, China; and qingle.meng@163.com xulei09060118@163.com asy331@sina.com.

Zitieren

APA

Li, R., Wang, F., Yang, R., Luo, R., Li, X., Wu, R., Hao, J., Xiong, L., Ju, H., Ai, S., Xu, L., & Meng, Q. (2026). Feasibility of Simulated Low-Count [ 18 F]FDG PET/MR for Patients with Pediatric Epilepsy. Journal of Nuclear Medicine Technology, jnmt.126.272511. https://doi.org/10.2967/jnmt.126.272511

Vancouver

Li R, Wang F, Yang R, Luo R, Li X, Wu R, et al. Feasibility of Simulated Low-Count [ 18 F]FDG PET/MR for Patients with Pediatric Epilepsy. Journal of Nuclear Medicine Technology. 2026:jnmt.126.272511. doi:10.2967/jnmt.126.272511

BibTeX
@article{Li2026,
  author = {Li, RuShuai and Wang, Feng and Yang, Rui and Luo, Rui and Li, Xiaoyuan and Wu, Runze and Hao, Jiaxin and Xiong, Liangshun and Ju, Heping and Ai, Shuyue and Xu, Lei and Meng, Qingle},
  title = {Feasibility of Simulated Low-Count [ 18 F]FDG PET/MR for Patients with Pediatric Epilepsy},
  journal = {Journal of Nuclear Medicine Technology},
  year = {2026},
  pages = {jnmt.126.272511},