Fachartikel in der Zeitschrift Journal of Nuclear Medicine Technology, online erschienen am 09.12.2025. Verfasst von Jacky W T Chen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Discipline of Medical Imaging Science, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia; wei-ting.chen@sydney…. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Workflow, Patient Satisfaction. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Long-axial-field-of-view (LAFOV) PET/CT scanners (>1 m axial field of view) provide an order-of-magnitude improvement in system sensitivity compared with conventional PET/CT systems, allowing clinicians to optimize scan protocols in terms of acquisition time, injected activity, and image quality. However, implementing these optimizations requires workflow changes, which may affect the patient experience and the quality of care provided. This study aims to contextualize the workflow changes for patients while comparing their experiences after a transition from conventional to LAFOV PET/CT at a metropolitan hospital.

Methods

Patient movement through a conventional PET/CT facility was observed for 1 working week. This was repeated 1 mo after transitioning to the LAFOV PET/CT system. The median times that patients spent in the uptake room, camera room, hallway, and toilet were compared. Additionally, a separate cohort of patients was invited to participate in a short survey regarding their experience during their PET/CT procedure. The same survey was provided to both cohorts. The questions used a 5-point Likert scale to assess patient concerns, physical discomforts, and perceptions of staff care. In total, 108 and 105 responses were collected for the conventional and LAFOV PET/CT cohorts, respectively.

Results

Patients who were scanned using the LAFOV PET/CT system spent significantly less time in the camera room and the uptake room (after injection and when including time waiting before injection). There was a significant reduction in the number of participants who felt that the scan was too long, were concerned about the radiation involved, were anxious, or reported feeling uncomfortable after transitioning to a LAFOV PET/CT system. No significant differences were observed between the 2 cohorts regarding their perceptions of the level of staff preparation and care provided or physical discomforts experienced, including claustrophobia.

Conclusion

Transitioning from a conventional to LAFOV PET/CT system reduced the time patients were required to remain stationary during the scan and resulted in decreased patient concerns. There was no evidence of a difference in the levels of physical discomfort, such as claustrophobia, experienced by the 2 cohorts despite the increased length of the gantry bore.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron Emission Tomography Computed TomographyWorkflowPatient SatisfactionHumansMaleFemaleMiddle AgedAgedAdult

Stichwörter der Autor:innen

long–axial-field-of-view PET/CTpatient experienceworkflow

Autor:innen und Institutionen

  • Discipline of Medical Imaging Science, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia; wei-ting.chen@sydney.edu.au.
  • Discipline of Medical Imaging Science, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia.
  • Medical Imaging Department, Prince of Wales Hospital, Sydney, New South Wales, Australia.
  • Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, New South Wales, Australia.
  • Brain and Mind Centre, University of Sydney, Sydney, New South Wales, Australia; and.
  • Sydney Imaging Core Research Facility, University of Sydney, Sydney, New South Wales, Australia.

Zitieren

APA

Chen, J. W. T., Rae, W. I. D., Kench, P. L., Bailey, D. L., Bailey, E. A., Roach, P. J., & Meikle, S. R. (2026). Impact of Long–Axial-Field-of-View PET/CT Workflow on the Patient Experience. Journal of Nuclear Medicine Technology, 54(1), 93-99. https://doi.org/10.2967/jnmt.125.270843

Vancouver

Chen JWT, Rae WID, Kench PL, Bailey DL, Bailey EA, Roach PJ, et al. Impact of Long–Axial-Field-of-View PET/CT Workflow on the Patient Experience. Journal of Nuclear Medicine Technology. 2026;54(1):93-99. doi:10.2967/jnmt.125.270843

BibTeX
@article{Chen2026,
  author = {Chen, Jacky W T and Rae, William I D and Kench, Peter L and Bailey, Dale L and Bailey, Elizabeth A and Roach, Paul J and Meikle, Steven R},
  title = {Impact of Long–Axial-Field-of-View PET/CT Workflow on the Patient Experience},
  journal = {Journal of Nuclear Medicine Technology},
  year = {2026},
  volume = {54},
  number = {1},
  pages = {93--99},
  doi = {10.2967/jnmt.125.270843}
}
Kostenlos starten →