Feasibility of Mercury-free Chemical Oxygen Demand (COD) Test with Excessive Addition of Silver Sulfate
Journal of Water and Environment Technology · 2018 · 16 (6) · 221-232
DOI: 10.2965/jwet.18-016 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Water and Environment Technology, 2018. Verfasst von Naoyuki Kishimoto und 1 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
The conventional chemical oxygen demand (COD) test requires mercuric sulfate (HgSO 4 ) for mask-ing chlorides (Cl − ) in a sample. Since the use of mercury (Hg) will be strictly restricted under the Minamata Convention on Mercury, the feasibility of Hg-free COD test by closed reflux, colorimetric method with excessive addition of silver sulfate (Ag 2 SO 4 ) was discussed in this research. Although Cl − contamination tended to increase the dichromate consumption even in the conventional COD test, the Ag 2 SO 4 dose in sulfuric acid reagent not less than 10.3 g/kg-H 2 SO 4 successfully masked Cl − not more than 500 mg-Cl/L. As a result of applying to 14 organic compounds with theoretical oxygen demand of 90 mg-O 2 /L, the Hg-free COD test tended to output slightly higher COD than the conventional one; the average degradation efficiency of 96% in the Hg-free test and 94% in the conventional test. The average accuracy for the Hg-free COD test was superior to the conventional one. In the economical viewpoint, the Hg-free COD test successfully cut off the chemical cost of Ag 2 SO 4 and HgSO 4 from 13,459 to 7,831 JPY/1,000 samples. Consequently, the Hg-free COD test was thought to be feasible for water samples containing Cl − not more than 500 mg-Cl/L.
Zitieren
APA
Kishimoto, N., & Okumura, M. (2018). Feasibility of Mercury-free Chemical Oxygen Demand (COD) Test with Excessive Addition of Silver Sulfate. Journal of Water and Environment Technology, 16(6), 221-232. https://doi.org/10.2965/jwet.18-016
Vancouver
Kishimoto N, Okumura M. Feasibility of Mercury-free Chemical Oxygen Demand (COD) Test with Excessive Addition of Silver Sulfate. Journal of Water and Environment Technology. 2018;16(6):221-232. doi:10.2965/jwet.18-016
BibTeX
@article{Kishimoto2018,
author = {Kishimoto, Naoyuki and Okumura, Masashi},
title = {Feasibility of Mercury-free Chemical Oxygen Demand (COD) Test with Excessive Addition of Silver Sulfate},
journal = {Journal of Water and Environment Technology},
year = {2018},
volume = {16},
number = {6},
pages = {221--232},
doi = {10.2965/jwet.18-016}
}
EUVIMED